RAID Configuration Commands
The IPSSEND RAID configuration commands include the following:
DRIVEVER
Use the DRIVEVER command to display the vendor ID, microcode version, and serial
number of a SCSI device. The IPSSEND program retrieves this information directly
from the device.
Supported operating systems: Windows NT, OS/2, NetWare,
OpenServer, UnixWare, and DOS
Command:
IPSSEND DRIVEVER Controller Channel SID
Replace:
° Controller with the ServeRAID controller number (1 to 8)
° Channel with the channel number for the device (1, 2, or 3)
° SID with the SCSI ID for the device (0 to 15)
GETCONFIG
Use the GETCONFIG command to display the ServeRAID adapter or controller
configuration information. This includes information about the firmware version,
initiator ID and rebuild rate, logical drive status, RAID level, and size, and
physical device type, SCSI ID, and PFA error.
Supported operating systems: Windows NT, OS/2, NetWare,
OpenServer, UnixWare, and DOS
Command:
IPSSEND GETCONFIG Controller Options
Replace:
° Controller with the ServeRAID controller number (1 to 8)
° Options with one of the following:
AD for adapter or controller information, LD for logical drive information,
PD for physical device information, AL (default) for all information.
HSREBUILD
Use the HSREBUILD command to set the ServeRAID adapter or controller hot-swap
rebuild feature on. Use a question mark (?) to display the current status of the
hot-swap rebuild feature.
Supported operating systems: Windows NT, OS/2, NetWare,
OpenServer, UnixWare, and DOS
Command:
IPSSEND HSREBUILD Controller Options
Replace:
° Controller with the ServeRAID controller number (1 to 8)
° Options with ON to enable the hot-swap rebuild feature, or ?
to display the status of the hot-swap rebuild feature.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.