System Board SCSI LEDs
A solid on or blinking system board SCSI LED indicated an
error was detected. (The blinks are followed by a pause.)
Note:
System Board SCSI LEDs
FRU/Action
1 blink followed by a
1. Check cables
pause
2. System Board
(Boot block checksum error)
3. DASD Backplane
2 blinks followed by a
1. Check cables
pause
2. System Board
(DRAM parity error)
3. DASD Backplane
3 blinks followed by a
1. Run the ServeRAID Flash program.
pause
2. Check cables
(Code block checksum
3. System Board
error, flash the ServeRAID
4. DASD Backplane
controller.)
4 blinks followed by a
1. Check cables
pause
2. System Board
(DRAM DATA)
3. DASD Backplane
5 blinks followed by a
1. Check cables
pause
2. System Board
(DRAM address error)
3. DASD Backplane
6 blinks followed by a
1. Run the ServeRAID Flash program.
pause
2. Check cables
(Code block checksum
3. System Board
error, flash the ServeRAID
4. DASD Backplane
controller.)
On (solid)
1. Check jumper J11, see 'System Board Jumpers'
2. Check cables
3. System Board
4. DASD Backplane
Please see the LEGAL - Trademark notice.