SCSI Error Codes


SCSI Error Codes

Error Code    FRU/Action
All SCSI Errors 1. External SCSI devices must be powered-on
   One or more of the following     before you power-on the server.
   might be causing the 2. The cables for all external SCSI devices
   problem:     are connected correctly.
   ° A failing SCSI device 3. If you have attached an external SCSI
   (adapter, drive,     device to the server, make sure the external
   controller)     SCSI termination is set to automatic.
   ° An improper SCSI 4. The last device in each SCSI chain is
   configuration or SCSI     terminated correctly.
   termination jumper 5. The SCSI devices are configured correctly.
   setting  
   ° Duplicate SCSI IDs in  
   the same SCSI chain  
   ° A missing or improperly  
   installed SCSI  
   terminator  
   ° A defective SCSI  
   terminator  
   ° An improperly installed  
   ° cable  
   ° A defective cable  