Error Symptoms


Error Symptoms

Error Symptom    FRU/Action
   CD is not working properly. 1. Clean the CD
  2. Clean the optical-head lens.
  3. CD-ROM Drive
   CD-ROM drive tray is not 1. Insert the end of a paper clip into the
   working.     manual tray-release opening.
   (The server must be 2. CD-ROM Drive
   powered-on.) If the server  
   is on and the tray does not  
   eject,  
   CD-ROM drive is not 1. Run Configuration/Setup, enabled primary IDE channel.
   recognized. 2. Check cables and jumpers.
  3. Check for correct device driver.
   Power switch does not work 1. Verify that the power-on control jumper
   and reset button does work.     on J32's extension cable is on pins 1 and 2.
  2. Power Switch Assembly
  3. System Board
   Diskette drive in-use light    If there is a diskette in the drive, verify that:
   stays on, or the system 1. The diskette drive is enabled in the
   bypasses the diskette drive,     configuration programs.
   or the diskette drive does 2. The diskette is good and not damaged.
   not work.     (Try another diskette if you have one.)
  3. The diskette is inserted correctly in the drive.
  4. The diskette contains the necessary files to
      start the server.
  5. The software program is OK.
  6. Run Diskette Drive Diagnostics.
  7. Cable
  8. Diskette Drive
  9. System Board
     
     If the diskette drive in-use light stays on, or
     the system continues to bypass the diskette drive,
     replace the diskette drive.
   Monitor problems (general) 1. Monitor
   Some IBM monitors have 2. Run Video Diagnostics. If
   their own self-tests. If you     diagnostics pass, the problem
   suspect a problem with the     may be a video driver
   monitor, refer to the 3. Display Adapter/System Board
   information that comes with  
   the monitor for adjusting  
   and testing instructions.  