| Power supply problems. |
'Power Supplies' (Type 3518) |
| Error Code/Symptom |
FRU/Action |
| E700 AC Failure |
1. Power Cord |
| (Power lost while the enclosure |
2. Power Supply |
| was running. The error is displayed |
|
| the next power-on.) |
|
| |
|
| E701 Power Supply |
1. Power Supply |
| (Redundant power supply indicates |
|
| a bad condition. Error is non-fatal |
|
| and can be cleared by pressing the |
|
| front panel Enter button.) |
|
| |
|
| E702 5V Failure |
1. Power Supply |
| (Enclosure 5V input is low or too |
2. System Board (Planar) |
| high. If too low non-fatal error is |
|
| written to the information panel. |
|
| If to high, enclosure is shutdown |
|
| and the error is displayed the |
|
| next power-on.) |
|
| |
|
| 703 12V Failure |
1. Power Supply |
| (Enclosure 12V input is low or too |
2. System Board (Planar) |
| high. If too low non-fatal error is |
|
| written to the information panel. |
|
| If to high, enclosure is shutdown |
|
| and the error is displayed the |
|
| next power-on.) |
|
| |
|
| E704 Fan Failure |
1. Fan |
| (In a non-fatal situation, a fan |
2. System Board (Planar) |
| has failed. If multiple fans fail, |
|
| the enclosure will not run until |
|
| the failure is corrected.) |
|
| |
|
| E705 Overheat |
1. Power Supply |
| (Power supply overheated and the |
2. Fan |
| enclosure was shutdown.) |
3. System Board (Planar) |
| |
|
| Blank Information Panel |
1. Information Display Cable |
| (If the Power OK indicator is on and |
2. Information Display Assembly |
| the fans are running, operation will |
3. System Board (Planar) |
| probably not be affected. However, |
|
| no diagnostic errors/messages will |
|
| be displayed.) |
|
| |
|
| No Power |
1. Power Cord |
| (Be sure the power cord and cables |
2. Power Supply |
| are properly plugged in, the expansion |
|
| enclosure is properly enabled and |
|
| powered on, and the electrical power |
|
| source is active.) |
|