POST Error Codes (Type 8644)


Error Codes (Type 8644)
Error Code/Symptom    FRU/Action
101 1. System Board
   (Timer tick interrupt failure) 2. Microprocessor
102 1. System Board
   (Timer 2 test failure) 2. Microprocessor
106 1. System Board
   (Diskette controller failure) 2. Microprocessor
110, 111 1. Memory DIMM
   (Memory parity error) 2. System Board
114 1. Adapter Memory
   (Option read only memory error) 2. System Board
121 1. Run Diagnostics
   (Hardware error) 2. System Board
151 1. Run Diagnostics
   (Real time clock failure) 2. Battery
  3. System Board
161 1. Battery
   (Real time clock battery failure)  
162 1. Run Configuration/Setup
   (A change in device 2. Failing Device
   configuration occured.) 3. Battery
   Possible causes: 4. System Board
   ° A new device installed  
   ° A device moved to a different  
   location/cable connection  
   ° A removed or disconnected device  
   ° A failing or unrecognized device  
   ° An external device is not turned on  
   ° Processor update code not installed  
   or not be found.  
   ° Running 'Erasing Lost or Forgotten  
   Passwords' procedure that erases  
   configuration data.  
   ° CMOS memory checksum error  
163 1. Run Configuration/Setup
   (Time of day not set) 2. Battery
  3. System Board
164 1. Run Configuration/Setup
   (Memory size does not match CMOS) 2. Dual Inline Memory Module
  3. Microprocessor
167 1. Perform the POST/BIOS (flash)
   (A microprocessor was installed     Update procedure with latest
   that is not supported by the current     POST/BIOS update
   POST/BIOS)  
175 1. System Board
   (System board/microprocessor error) 2. Microprocessor
176 1. Run Configuration/Setup
   (Computer cover or cable  
   cover was removed without  
   a key being used)  
186 1. Run Configuration/Setup
   (System board or 2. System Board
   security hardware error)  
187 1. See POST error 162
   (Administrator password and  
   see POST error 162)  
   boot sequence have been cleared,  
20X 1. Memory installed incorrectly
   (Memory controller error) 2. Memory Module
  3. Microprocessor Board
  4. System Board
301 303 1. Keyboard
   (Keyboard failure) 2. System Board
601 1. Diskette Drive Cable
   (Diskette drive error) 2. Diskette Drive
  3. System Board
602 1. Try another startable
   (Diskette damaged or     diskette that is formatted
   formatted incorrectly.)     correctly and is in good condition
  2. Diskette Drive
604 1. Run Configuration/Setup
   (Diskette Drive failure) 2. Diskette Drive
  3. Diskette Drive Cable
  4. System Board
662 1. Run Configuration/Setup
   (Diskette drive     and Diagnostics
   configuration error) 2. Diskette Drive
  3. Diskette Drive Cable
  4. System Board
762 1. Run Configuration/Setup
   (Math coprocessor 2. Processor
   configuration error) 3. System Board
11XX 1. Disconnect external cable on serial port.
   (Serial port configuration 2. Run Configuration/Setup
   error) 3. System Board
1762 1. Run Configuration/Setup
   (Hard disk configuration 2. Cable
   error) 3. Diskette Drive
  4. System Board
178X 1. Run diagnostics
   (A hard disk drive or a 2. Hard Disk Drive
   primary or secondary IDE 3. Primary or Secondary IDE Device
   device error)  
1800 1. Run Configuration/Setup
   (PCI adapter interrupt 2. Run EISA Configuration
   request error) 3. Failing Adapter
  4. System Board
1801 1. Run Configuration/Setup
   (PCI adapter memory request error) 2. Run EISA Configuration
  3. Failing Adapter
  4. System Board
1802 1. Run Configuration/Setup
   (PCI adapter I/O address 2. Failing Adapter
   request error) 3. System Board
1803 1. Run Configuration/Setup
   (PCI adapter memory 2. Failing Adapter
   address request error) 3. System Board
1804 1. Run Configuration/Setup
   (PCI adapter memory 2. Move failing adapter to slot 1 or 2
   address request error) 3. Failing Adapter
  3. System Board
1805 1. Remove Failing PCI Adapter
   (PCI adapter ROM checksum error) 2. System Board
1850 1. Verify all adapter settings
   (Plug and Play adapter hardware     in the Configuration/Setup
   interrupt request error     Utility program.
   See 'Adapters'.)  
1851 1. Verify all memory resources
   (Plug and Play adapter memory     in the Configuration/Setup
   resources request error)     Utility program
1852 1. Verify all adapter settings
   (Plug and Play adapter I/O     in the Configuration/Setup
   request error.     Utility program
   See 'Config./Setup Utility Program Menus'  
   See 'Adapters'.)  
1853 1. Verify all adapter settings
   (Plug and Play adapter memory     in the Configuration/Setup
   request error.     Utility program
   See 'Config./Setup Utility Program Menus'  
   See 'Adapters'.)  
1854 1. Verify all adapter settings
   (Plug and Play adapter memory     in the Configuration/Setup
   address request error.     Utility program
   See 'Config./Setup Utility Program Menus'  
   See 'Adapters'.)  
1855 1. Remove all adapters and
   (Plug and Play adapter read-only     reinstall them one at a time
   memory (ROM) error).     Power-on the server after each
      installation until you isolate
      the failing adapter
1856 1. Verify all adapter settings
   (Plug and Play adapter DMA address     in the Configuration/Setup
   request error.     Utility program
   See 'Config./Setup Utility Program Menus'     installation until you isolate
   See 'Adapters'     the failing adapter
1962 1. Run Configuration/Setup / See > Tip H166357
   (No valid startup devices 2. Check the cable connections.
   where found). 3. System Board.
8603 1. Pointing Device
   (Pointing device has been 2. System Board
   removed).  
I9990301 1. Run Configuration/Setup
   (Fixed boot sector error,  
   no operating system installed)  


Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.