BCS/ECS Configuration Register Codes (Server 330 - x1Y, Pxx)



BCS/ECS Configuration Register Codes (Server 330 - x1Y, Pxx)

BCS
8421-8421
ECS
8421-8421
Explanation and Possible Recovery Action
BCS not
in table
ECS not
in table
Explanation: The Adapter is not functioning
properly.
Action: Run ServeRAID diagnostics and
display message M4.
0000-0000
(X'00')
0000-0001
(X'01')
Explanation: Invalid Flash configuration.
Action: Run ServeRAID configuration and
display message M2.
0000-0000
(X'00')
0000-0010
(X'02')
Explanation: Invalid NVRAM configuration.
Action: Run ServeRAID configuration and
display message M2.
0000-0000
(X'00')
0000-0011
(X'03')
Explanation: Invalid Flash and NVRAM
configuration.
Action: Run ServeRAID configuration
and display message M3.
0000-0001
(X'01')
0000-1000
(X'08')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) are not
responding.
Action: Press F1, F2, F4, F10
0000-0001
(X'01')
0001-1000
(X'18')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) and
HSP/SHS drive(s) are not responding.
Action: Press F1, F2, F4, F10
0000-0001
(X'01')
0010-1000
(X'28')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) and
RDY/SBY drive(s) are not responding.
Action: Press F1, F2, F4, F10
0000-0001
(X'01')
0011-1000
(X'38')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) and
HSP/SHS, and RDY/SBY
drive(s) are not responding.
Action: Press F1, F2, F4, F10
0000-0001
(X'01')
0100-1000
(X'48')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) are
not responding and unidentified drive(s)
were found.
Action: Press F1, F2, F4, F10
0000-0001
(X'01')
0101-1000
(X'58')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) and
HSP/SHS drive(s) are not responding and
unidentified drive(s) were found.
Action: Press F1, F2, F4, F10
0000-0001
(X'01')
0110-1000
(X'68')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) and
RDY/SBY drive(s) are not responding and
unidentified drive(s) were found.
Action: Press F1, F2, F4, F10
0000-0001
(X'01')
0111-1000
(X'78')
Explanation: No configuration was found
in drive(s) and ONL/RBL drive(s) and
HSP/SHS, and RDY/SBY drive(s) are not
responding and unidentified drive(s) were
found.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1000-1000
(X'88')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL drive(s) are not responding.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1001-1000
(X'98')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL and HSP/SHS drive(s) are
not responding.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1010-1000
(X'A8')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL and RDY/SBY drive(s) are
not responding.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1011-1000
(X'B8')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL and HSP/SHS, and RDY/SBY drive(s)
are not responding.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1100-1000
(X'C8')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL drive(s) are not responding and
unidentified drive(s) were found.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1101-1000
(X'D8')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL and HSP/SHS drive(s) are not
responding and unidentified drive(s)
were found.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1110-1000
(X'E8')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL and RDY/SBY drive(s) are not
responding and unidentified drive(s)
were found.
Action: Press F1, F2, F4, F10
0000-0011
(X'03')
1111-1000
(X'F8')
Explanation: A drive was imported from
another system and it has valid configuration
and ONL/RBL and HSP/SHS, and RDY/SBY drive(s)
are not responding and unidentified drive(s)
were found.
Action: Press F1, F2, F4, F10
0000-0111
(X'07')
0000-1000
(X'08')
Explanation: ONL/RBL drive(s) are
not responding.
Action: Press F1, F2, F10
0000-0111
(X'07')
0000-1100
(X'0C')
Explanation: ONL/RBL drive(s) are
not responding and drive in wrong ID.
Action: Press F1, F2, F3, F10
0000-0111
(X'07')
0001-1000
(X'18')
Explanation: ONL/RBL and HSP/SHS
drive(s) are not responding.
Action: Press F1, F2, F10
0000-0111
(X'07')
0001-1110
(X'1C')
Explanation: ONL/RBL and HSP/SHS
drive(s) are not responding and drive in
wrong ID.
Action: Press F1, F2, F3, F10
0000-0111
(X'07')
0010-1000
(X'28')
Explanation: ONL/RBL and RDY/SBY
drive(s) are not responding.
Action: Press F1, F2, F10
0000-0111
(X'07')
0010-1100
(X'2C')
Explanation: ONL/RBL and RDY/SBY
drive(s) are not responding and drive in
wrong ID.
Action: Press F1, F2, F3, F10
0000-0111
(X'07')
0011-1000
(X'38')
Explanation: ONL/RBL, RDY/SBY and
HSP/SHS drive(s) are not responding.
Action: Press F1, F2, F10
0000-0111
(X'07')
0011-1100
(X'3C')
Explanation: ONL/RBL, RDY/SBY and
HSP/SHS drive(s) are not responding and
drive in wrong ID.
Action: Press F1, F2, F3, F10
0000-0111
(X'07')
0100-1000
(X'48')
Explanation: ONL/RBL drive(s) are
not responding and unidentified drive(s)
were found.
Action: Press F1, F2, F10
0000-0111
(X'07')
0100-1100
(X'4C')
Explanation: ONL/RBL drive(s) are
not responding, drive in wrong ID, and
unidentified drive(s) were found.
Action: Press F1, F2, F3, F10
0000-0111
(X'07')
0101-1000
(X'58')
Explanation: ONL/RBL drive(s) and
HSP/SHS drive(s) are not responding and
unidentified drive(s) were found.
Action: Press F1, F2, F10
0000-0111
(X'07')
0101-1100
(X'5C')
Explanation: ONL/RBL drive(s) and
HSP/SHS drive(s) are not responding, drive
in wrong ID, and unidentified drive(s) were
found.
Action: Press F1, F2, F3, F10
0000-0111
(X'07')
0110-1000
(X'68')
Explanation: ONL/RBL and RDY/SBY
drive(s) are not responding, and unidentified
drive(s) were found.
Action: Press F1, F2, F10
0000-0111
(X'07')
0110-1100
(X'6C')
Explanation: ONL/RBL and RDY/SBY
drive(s) are not responding, drive in wrong
ID, and unidentified drive(s) were found.
Action: Press F1, F2, F3, F10
0000-0111
(X'07')
0111-1000
(X'78')
Explanation: ONL/RBL, RDY/SBY, and
HSP/SHS drive(s) are not responding and
unidentified drive(s) were found.
Action: Press F1, F2, F10
0000-0111
(X'07')
0111-1100
(X'7C')
Explanation: ONL/RBL, RDY/SBY, and
HSP/SHS drive(s) are not responding, drive
in wrong ID, and unidentified drive(s)
were found.
Action: Press F1, F2, F3, F10
0000-1001
(X'09')
0000-0000
(X'00')
Explanation: No error occurred
Action: None
0000-1001
(X'00')
0001-0000
(X'10')
Explanation: HSP/SHS drive(s) are
not responding.
Action: Press F1, F2, F10
0000-1001
(X'09')
0010-0000
(X'20')
Explanation: RDY/SBY drive(s) are
not responding.
Action: Press F1, F2, F10
0000-1001
(X'09')
0011-0000
(X'30')
Explanation: HSP/SHS and RDY/SBY
drive(s) are not responding.
Action: Press F1, F2, F10
0000-1111
(X'0F')
0000-0000
(X'00')
Explanation: No error occurred.
Action: None
0000-1111
(X'0F')
0001-0000
(X'10')
Explanation: HSP/SHS drives are
not responding.
Action: Press F1, F2, F10
0000-1111
(X'0F')
0010-0000
(X'02')
Explanation: RDY/SBY drives are
not responding.
Action: Press F1, F2, F10
0000-1111
(X'0F')
0011-0000
(X'30')
Explanation: HSP/SHS and RDY/SBY
drive(s) are not responding.
Action: Press F1, F2, F10


Please see the LEGAL  -  Trademark notice.