RAID POST Error Codes (Server 330 - x1Y, Pxx)



RAID POST Error Codes (Server 330 - x1Y, Pxx)

Once the RAID test has completed, the following register information is displayed on the screen before returning to the Diagnostic Control program:

Hdwr: ISPR= aaaa BCS= bb ECS= cc

The number aaaa is the controller POST, it should normally read EF10 which indicates NO ERROR BCS and ECS are configuration registers.

NOTE: For a full list of the BCS ECS configuration error messages, refer to the manual for the RAID adapter.

Error Code    FRU/Action
1XXX 1. System Board
   ServeRAID POST - Flash Checksum error  
2XXX 1. System Board
   ServeRAID POST - Code DRAM error  
3XXX 1. System Board
   ServeRAID POST - NVRAM error  
4XXX 1. System Board
   ServeRAID POST - Time/Cache  
   Memory Controller error  
5XXX 1. System Board
   ServeRAID POST - Cache  
   Memory Controller error  
6XXX 1. System Board
   ServeRAID POST - Cache DRAM error  
7XXX 1. System Board
   ServeRAID POST - Host/Local  
   PCI Bus Interface error  
8XXX 1. System Board
   ServeRAID POST - SCSI IOP error  
9XXX 1. System Board
   ServeRAID POST - SCSI  
   Termination error  
AXXX 1. System Board
   ServeRAID POST - SCSI IOP error  
BXXX 1. Cable
   ServeRAID POST - SCSI 2. System Board
   Bus Interface error  