| Symptom / Error | FRU / Action in Sequence |
|---|---|
| An icon in the LCD information | 1. Reseat the keyboard cable in the video card connector. |
| panel remains off or on, but | 2. Reseat the LCD information panel cable connectors |
| the system runs correctly. | in the keyboard. |
| 3. Keyboard | |
| 4. Video card | |
| 5. System board |