Numeric Error Codes (SelectaDock II - III)


Numeric Error Codes
Symptom or Error    FRUs of the SelectaDock
     Sequence of Actions
10X, 11X 1. Adapter in slot (if used)
   101: Interrupt failure. 2. Riser card
   102: Timer failure. 3. Main card
   103: Timer interrupt failure.  
   104: Protected mode failure.  
   105: Last 8042 command not accepted.  
   107: NMI test failure.  
   108: Timer bus test failure.  
   109: Low meg-chip select test.  
195     Do the following steps:
   (The computer was docked to the    a. Power-off and undock the system.
   SelectaDock Docking system while    b. Power-on and shut down the system.
   in hibernation mode.)    c. Power-off and dock the system.
1XX 1. See the Hardware Maintenance Manual of the computer.
      If the problem remains, go to Undetermined Problems
2XX 1. See the Hardware Maintenance Manual of the computer.
   201: Memory data error. 2. Main card
   202: Memory line error 00-15.  
   203: Memory line error 16-23.  
   205: Memory test failure on on-board memory.  
   221: ROM to RAM remap error.  
3XX 1. See External Keyboard
6XX 1. Before changing any devices, run the diagnostic test.
      (See the How to Run the Diagnostics)
  2. FDD external attachment kit
  3. Diskette drive assembly
  4. Riser card
11XX, 12XX 1. Serial devices
  2. Communication cable
  3. Riser card
17XX 1. Hard disk drive (2.5-inch ThinkPad hard disk drive)
  2. Main card
24XX 1. Main card
  2. Riser card
860X 1. Mouse
  2. External keyboard
  3. Riser card
I9990301, I9990302 1. See the Hardware Maintenance Manual for the computer.
   I9990305  
   Not shown above 1. See the Hardware Maintenance Manual for the computer.
  2. See Undetermined Problems.


Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.