| Symptom/Error |
SelectaDock Docking System |
| |
FRUs Sequence of Actions |
| 10X, 11X |
1. Adapter in slot (if used) |
| 101: Interrupt failure. |
2. Riser card |
| 102: Timer failure. |
3. Main card |
| 103: Timer interrupt failure. |
|
| 104.: Protected mode failure. |
|
| 105: Last 8042 command not accepted. |
|
| 107: NMI test failure. |
|
| 108: Timer bus test failure. |
|
| 109: Low meg-chip select test. |
|
| 195 |
1. Do the following steps. |
| (The computer was docked to the |
a. Power-off and undock the system. |
| SelectaDock Docking System while |
b. Power-on and shut down the system. |
| in hibernation mode.) |
c. Power-off and dock the system. |
| 1XX |
1. See the Hardware Maintenance Manual |
| |
of the computer. |
| |
If the problem remains, go to 'Undetermined Problems' |
| 2XX |
1. See the Hardware Maintenance Manual. |
| 201: Memory data error. |
of the computer. |
| 202: Memory line error 00-15. |
2. Main card |
| 203: Memory line error 16-23. |
|
| 205: Memory test failure on on-board memory. |
|
| 221: ROM to RAM remap error. |
|
| 3XX |
1. See 'External Keyboard' |
| 6XX |
1. Before changing any devices, |
| |
run the diagnostic test. |
| |
(See the 'How to Run the Diagnostics') |
| |
2. FDD external attachment kit |
| |
3. Diskette drive assembly |
| |
4. Riser card |
| 11XX, 12XX |
1. Serial devices |
| |
2. Communication cable |
| |
3. Riser card |
| 17XX |
1. Hard disk drive |
| |
2. Main card |
| |
(2.5-inch ThinkPad hard disk drive) |
| 24XX |
1. Main card |
| |
2. Riser card |
| 860X |
1. Mouse |
| |
2. External keyboard |
| |
3. Riser card |
| I9990301, I9990302 |
1. See the Hardware Maintenance Manual. |
| I9990305 |
of the computer. |
| Not shown above |
1. See the Hardware Maintenance Manual |
| |
2. See 'Undetermined Problems'. |
| |
of the computer. |