External Diskette Drive Checkout (2524)



External Diskette Drive Checkout

Use the following procedure to isolate the diskette problem to a controller, drive or diskette. A scratch, write enabled 2HD diskette is required.
  1.  Select the icon FDD on the TEST MENU.  By doing this, the controller test and the drive read/write test run. If the  controller test detects an error, FRU code 10 appears. In this case, replace the system board.
  2.  If the controller test run without errors, follow the instructions on the  screen and insert a scratch diskette.
  3.  If the drive test detects an error, FRU code 50 appears. If the diskette media  are known to be good, replace the drive or the drive cable.