| Symptom/Error |
FRU/Action |
| 10X |
1. System Board |
| 110 |
1. Go to 'Memory Checkout' |
| |
2. IC DRAM Card or DIMM Card |
| |
3. System Board |
| 111 |
1. Go to 'Memory Checkout' |
| |
2. Expansion Unit/Port Replicator |
| |
3. System Board |
| 158 |
1. Set a HDP. |
| (HDP was not set even |
|
| though the supervisor |
|
| password is set.) |
|
| 159 |
1. Set a correct HDP. |
| (HDP is not set the same |
|
| as the supervisor password.) |
|
| 161 |
1. Go to 'Checking the Backup Battery' |
| |
2. Backup Battery |
| |
3. System Board |
| 163 |
1. Set Time and Date. |
| (Time and Date was not set.) |
2. System Board |
| 173 |
1. Select OK in the error screen |
| (Configuration data were lost.) |
then set time and date |
| |
2. Backup Battery |
| |
3. System Board |
| 174 |
1. Check Device Configuration. |
| (Perform |
2. System Board |
| 'Checking the Installed Devices List' |
3. Diskette Drive Assembly |
| before changing any FRUs) |
4. Hard Disk Drive Assembly |
| 175, 177, 178 |
1. System Board |
| 183 |
1. Have the user examine the password. |
| (Incorrect password entered |
|
| at the supervisor password |
|
| prompt.) |
|
| 184 |
1. Reset the POP in Easy-Setup. |
| (POP check sum error.) |
|
| 185 |
1. Reset the startup sequence |
| (The startup sequence is |
in Easy-Setup. |
| not valid. |
|
| Suspect that power was off |
|
| when the startup sequence |
|
| was being updated.) |
|
| 186 |
1. System Board |
| 188 |
1. Set the system identification |
| |
using the ThinkPad 750Ce |
| |
hardware maintenance diskette. |
| 190 |
1. Go to 'Checking the Battery Pack' |
| (Depleted battery pack was |
|
| installed when the power was on.) |
|
| 191XX |
1. System Board |
| |
2. Processor card |
| 195 |
1. Check if the configuration was changed. |
| (The configuration read |
For example, check if the disk drive is |
| from the hibernation area |
from another computer |
| does not match the actual |
|
| configuration.) |
|
| 196 |
1. Run the hard disk drive test. |
| (Read error occurred in the |
2. Hard Disk Drive |
| hibernation area of the HDD.) |
|
| 199XX |
1. System Board |
| 1XX |
1. System Board |
| 2XX |
1. Go to 'Memory Checkout' |
| |
2. IC DRAM Card, DIMM, or DIMM Adapter |
| |
3. System Board |
| 301, 303, 304, 305, 3XX |
1. Go to 'Keyboard / Auxiliary Input Device Checkout' |
| |
2. Keyboard |
| |
3. Video Card |
| |
4. External Numeric Keypad |
| |
5. External Keyboard |
| |
6. Keyboard/Mouse Cable |
| |
7. System Board |
| 601, 6XX |
1. Go to 'Diskette Drive Test' |
| |
2. Diskette Drive Assembly |
| |
3. Diskette |
| |
4. System Board |
| 602 |
1. Go to 'Diskette Drive Test' |
| (Diskette read error.) |
2. Diskette |
| |
3. Diskette Drive Assembly |
| 604 |
1. Go to 'Diskette Drive Test' |
| (Non-acceptable ID was read |
2. Diskette Drive Assembly |
| from the diskette drive.) |
3. System Board |
| 11XX |
1. Serial Device (First) |
| |
2. Communication Cable |
| |
3. System Board |
| 12XX |
1. Serial Device (Second) |
| |
2. Communication Cable |
| |
3. System Board |
| 17XX |
1. Hard Disk Drive |
| |
2. System Board |
| 24XX |
1. System Board |
| |
2. Video Card |
| 808X |
1. PCMCIA Slot Assembly |
| |
2. PCMCIA Device |
| |
3. System Board |
| 860X |
1. External Mouse |
| (Pointing device error when |
2. External Keyboard |
| TrackPoint III is disabled.) |
3. System Board |
| 861X |
1. Reseat the keyboard Track Point III |
| (Pointing device error when |
cable at the interposer card |
| TrackPoint III is enabled.) |
See '1080 Keyboard Unit' |
| |
2. Keyboard |
| |
3. External Mouse |
| |
4. Video Card |
| |
5. System Board |
| I9990301 |
1. Reseat the boot device. |
| I9990302 |
2. Check the startup sequence for the correct |
| I9990305 |
boot device. |
| |
3. Check that operating system has no failure |
| |
or is installed correctly. |
| I9990303 |
1. System Board |
| Other codes not listed above |
1. Go to 'Undetermined Problems' |