Numeric Error Codes



Numeric Error Codes
Symptom/Error    FRU/Action
10X 1. System Board
110 1. Go to 'Memory Checkout'
  2. IC DRAM Card or DIMM Card
  3. System Board
111 1. Go to 'Memory Checkout'
  2. Expansion Unit/Port Replicator
  3. System Board
158 1. Set a HDP.
   (HDP was not set even  
   though the supervisor  
   password is set.)  
159 1. Set a correct HDP.
   (HDP is not set the same  
   as the supervisor password.)  
161 1. Go to 'Checking the Backup Battery'
  2. Backup Battery
  3. System Board
163 1. Set Time and Date.
   (Time and Date was not set.) 2. System Board
173 1. Select OK in the error screen
   (Configuration data were lost.)     then set time and date
  2. Backup Battery
  3. System Board
174 1. Check Device Configuration.
   (Perform 2. System Board
   'Checking the Installed Devices List' 3. Diskette Drive Assembly
   before changing any FRUs) 4. Hard Disk Drive Assembly
175, 177, 178 1. System Board
183 1. Have the user examine the password.
   (Incorrect password entered  
   at the supervisor password  
   prompt.)  
184 1. Reset the POP in Easy-Setup.
   (POP check sum error.)  
185 1. Reset the startup sequence
   (The startup sequence is     in Easy-Setup.
   not valid.  
   Suspect that power was off  
   when the startup sequence  
   was being updated.)  
186 1. System Board
188 1. Set the system identification
      using the ThinkPad 750Ce
      hardware maintenance diskette.
190 1. Go to 'Checking the Battery Pack'
   (Depleted battery pack was  
   installed when the power was on.)  
191XX 1. System Board
  2. Processor card
195 1. Check if the configuration was changed.
   (The configuration read     For example, check if the disk drive is
   from the hibernation area     from another computer
   does not match the actual  
   configuration.)  
196 1. Run the hard disk drive test.
   (Read error occurred in the 2. Hard Disk Drive
   hibernation area of the HDD.)  
199XX 1. System Board
1XX 1. System Board
2XX 1. Go to 'Memory Checkout'
  2. IC DRAM Card, DIMM, or DIMM Adapter
  3. System Board
301, 303, 304, 305, 3XX 1. Go to 'Keyboard / Auxiliary Input Device Checkout'
  2. Keyboard
  3. Video Card
  4. External Numeric Keypad
  5. External Keyboard
  6. Keyboard/Mouse Cable
  7. System Board
601, 6XX 1. Go to 'Diskette Drive Test'
  2. Diskette Drive Assembly
  3. Diskette
  4. System Board
602 1. Go to 'Diskette Drive Test'
   (Diskette read error.) 2. Diskette
  3. Diskette Drive Assembly
604 1. Go to 'Diskette Drive Test'
   (Non-acceptable ID was read 2. Diskette Drive Assembly
   from the diskette drive.) 3. System Board
11XX 1. Serial Device (First)
  2. Communication Cable
  3. System Board
12XX 1. Serial Device (Second)
  2. Communication Cable
  3. System Board
17XX 1. Hard Disk Drive
  2. System Board
24XX 1. System Board
  2. Video Card
808X 1. PCMCIA Slot Assembly
  2. PCMCIA Device
  3. System Board
860X 1. External Mouse
   (Pointing device error when 2. External Keyboard
   TrackPoint III is disabled.) 3. System Board
861X 1. Reseat the keyboard Track Point III
   (Pointing device error when     cable at the interposer card
   TrackPoint III is enabled.)     See '1080 Keyboard Unit'
  2. Keyboard
  3. External Mouse
  4. Video Card
  5. System Board
I9990301 1. Reseat the boot device.
   I9990302 2. Check the startup sequence for the correct
   I9990305     boot device.
  3. Check that operating system has no failure
      or is installed correctly.
I9990303 1. System Board
Other codes not listed above 1. Go to 'Undetermined Problems'


Please see the LEGAL  -  Trademark notice.