Symptom/Error | FRU/Action |
---|---|
Indicator incorrectly remains on | 1. Reseat the inverter card. |
or off, but system runs correctly. | 2. Inverter Card. |
3. Top System Board. | |
Battery status indicator blinks | 1. Check that a fully charged battery is |
green and beeps three times | installed. |
at power-on or Resume. | 2. Battery Pack |
3. Reseat Top and Bottom System Boards together. | |
4. Top System Board. | |
5. Bottom System Board. | |
Battery status indicator blinks | 1. Check the card-to-card connection. |
green at power-on. | Reseat Top and Bottom System Boards together. |
2. Top System Board. | |
3. Bottom System Board. | |
Battery status indicator does | 1. This is normal operation if charging continues. |
not turn on when battery fuel | Leave the computer charging, and then |
gauge is over 90% but less | recheck the battery fuel gauge a short |
than 100% | time later to see whether the charge has |
increased. |