Seagate Technology, Inc. Scotts Valley, CA Specifications and jumper settings: Older CDC/Imprimis Wren products NOT converted to new Seagate model numbers (see the file OLD2NEW.TXT for conversion chart) =========================================================================== 9415-5 xx (Wren 1) ST506 MFM Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 9415-5 21 Wren1 ST412 697 3 17 35,547 18,200,064 0 9415-5 25 Wren1 ST412 697 4 17 47,396 24,266,752 0 9415-5 28 Wren1 ST412 697 4 17 47,396 24,266,752 0 9415-5 36 Wren1 ST412 697 5 17 59,245 30,333,440 0 9415-5 38 Wren1 ST412 733 5 17 62,305 31,900,160 0 Drive Sel ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ o o o o o ³ Term 1³ o o o o o ³ 14 pin dip ³ ÚÄÄÄÄÄÄÄÄÄ¿ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ³ O O O O ³ Power 1 2 3 4 Radial \ÄÄÄÄÄÄÄÄÄ/ Command ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 12 G G 5 ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Data ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ =========================================================================== 94151-xx (Wren 2) SCSI (SASI subset) Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94151-25 Wren2 SASI 921 3 36 n/a(256 byte/sct) 94151-27 Wren2 SASI 921 3 19 n/a(512 byte/sct) 94151-42 Wren2 SASI 921 5 36 n/a(256 byte/sct) 94151-44 Wren2 SASI 921 5 19 n/a(512 byte/sct) 94151-59 Wren2 SASI 921 7 36 n/a(256 byte/sct) 94151-62 Wren2 SASI 921 7 19 n/a(512 byte/sct) 94151-76 Wren2 SASI 921 9 36 n/a(256 byte/sct) 94151-80 Wren2 SASI 921 9 19 n/a(512 byte/sct) ÚÄÄ Drive Select ID ³ ÚÄÄÄÄÄÄÁÄÄÄÄÄÄ¿ Ú12ÄGÄGÄ5Ä¿ Ú3 ea.ÄÄÄ¿ o o o o o o o o o ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸ ³ 0 0 0 0 ³ ³Terminator o o o o o o o o o ³:::SCSI:Cable:::::::::::1³ \ÄÄÄÄÄÄÄÄÄ/ ÀÄÄÄÄÄÄÄÄÙ ÍSÍ0Í1Í2Í3Í4Í5Í6Í7ÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ³ Heads = 3 5 7 9 ÀÄÄ Sector Block Size ON = 512 bytes/block 94151-27, 44, 62, 80 OFF = 256 bytes/block 94151-25, 42, 59, 76 =========================================================================== 94155-xxx (Wren 2) ST412 RLL Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94155-120 Wren2 ST412 960 8 26 199,680 102,236,160 Drive Sel ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ o o o o o ³ Term 1³ o o o o o ³ 14 pin dip ³ ÚÄÄÄÄÄÄÄÄÄ¿ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ³ O O O O ³ Power 1 2 3 4 Radial \ÄÄÄÄÄÄÄÄÄ/ Command ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 12 G G 5 ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Data ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ =========================================================================== 94155-xxx (Wren 2) ST412 MFM Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94155-36 Wren2 ST412 697 5 17 59,245 30,333,440 128 94155-48 Wren2 ST412 925 5 17 78,625 40,256,000 ? 94155-57 Wren2 ST412 925 6 17 94,350 48,307,200 ? 94155-67 Wren2 ST412 925 7 17 110,075 56,358,400 ? 94155-77 Wren2 ST412 925 8 17 125,800 64,409,600 ? Drive Sel ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ o o o o o ³ Term 1³ o o o o o ³ 14 pin dip ³ ÚÄÄÄÄÄÄÄÄÄ¿ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ³ O O O O ³ Power 1 2 3 4 Radial \ÄÄÄÄÄÄÄÄÄ/ Command ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 12 G G 5 ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Data ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ =========================================================================== 94156-xx (Wren 2) ESDI (MFM Recordiing Mode) Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94156-48 Wren2 ESDI 925 5 17 78,625 40,256,000 94156-67 Wren2 ESDI 925 7 17 110,075 56,358,400 94156-86 Wren2 ESDI 925 9 17 141,525 72,460,800 Drive Selects Ä¿ (binary) ÄÄÄÁÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ 12 G G 5 4 2 1 ³ Term 1³ ÚÄÄÄÄÄÄÄÄÄ¿ o o o ³ 14 pin dip ³ ÚCommand Cable ³ 0 0 0 0 ³ Power o o o ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÙÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 \ÄÄÄÄÄÄÄÄÄ/ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÚÄÄÄÄÄÄÄÄÄÄ¿1 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÀÄÄÄÄÄÄÄÄÄÄÙ ÀData Cable ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ Factory Test (off is normal) ³ ÚÄÄÄÄÄÄÄÄÄÄÄ Motor Start option enable ³ ³ ÚÄ Serial Mode (always on) ³ ³ SW1 ³ Sectors ³ 1 2 3 4 5 6 7 ÍÍÍÍÍÍÍÍÍÍØÍTÍMÍÍÍÍÍÍÍÍÍSÍÍ (512) 17 ³ 1 1 16 ³ 0 1 (located at front of drive 34 ³ 1 0 behind the front plate) 32 ³ 0 0 Address Mark ³ 1 1 1=on; 0=off Byte Clock ³ 0 1 Sector Pulse ³ 0 0 Sector Pulse ³ 1 0 =========================================================================== 94161-xxx (Wren 3) SCSI Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94161- 86 Wren3 SCSI 969 5 35 169,575 86,822,400 94161-101 Wren3 SCSI 969 5 34 164,730 84,341,760 94161-103 Wren3 SCSI 969 6 35 203,490 104,186,880 94161-121 Wren3 SCSI 969 7 35 237,405 121,551,360 94161-138 Wren3 SCSI 969 8 35 271,320 138,915,840 94161-141 Wren3 SCSI 969 7 34 230,622 118,078,464 94161-155 Wren3 SCSI 969 9 34 296,514 151,815,168 (3 by 5 configuration jumper block) ÚÄÄÄÄÄ Motor Start Option enable (horizontal) ³ ÚÄ N/A ³ ³ ÚÄ Terminator Power from Bus oÁo xÁx oij (upper 2 pins) Ú12ÄGÄGÄ5Ä¿ ÚÄÄÄÄÄÄÄÄ¿ o o o o ÚoÂÙ ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸ ³ 0 0 0 0 ³ ³Terminator o o o o ³o³ ³:::SCSI:Cable:::::::::::1³ \ÄÄÄÄÄÄÄÄÄ/ ÀÄÄÄÄÄÄÄÄÙ ÍÍÍÍÍ4Í2Í1ÍPÍÏTÏÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍØÍØÍØÍØÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÀÄÅÄÙ ³ ³ ³ ³ À Terminator Power (+5v) from drive (lower 2 pins) ³ ÀÄÄÄ Parity Check Option Enable (vertical) ÀÄÄÄÄÄÄÄ Drive Select ID's (vertical) (2 by 7 configuration jumper block) Terminator Power from Bus (horizontal) ³ Ú12ÄGÄGÄ5Ä¿ ÚÄÄÄÄÄÄÄÄ¿ o o o o o oÁo ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸ ³ 0 0 0 0 ³ ³Terminator o o o o o x o ³:::SCSI:Cable:::::::::::1³ \ÄÄÄÄÄÄÄÄÄ/ ÀÄÄÄÄÄÄÄÄÙ ÍMÍ4Í2Í1ÍPÍTÍTÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍØÍØÍØÍØÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ³ ÀÄÅÄÙ ³ ³ ³ ³ ³ ÀÄ Terminator Power (+5v) from drive (lower 2 pins) ³ ³ ÀÄÄÄÄÄ Parity Check Option Enable (vertical) ³ ÀÄÄÄÄÄÄÄÄÄ Drive Select ID's (vertical) ÀÄÄÄÄÄÄÄÄÄÄÄÄÄ Motor Start Option enable =========================================================================== 94166-xxx (Wren 3) ESDI Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94166-101 Wren3 ESDI 969 5 36 174,420 89,303,040 94166-121 Wren3 ESDI 969 6 36 209,304 107,163,648 94166-141 Wren3 ESDI 969 7 36 244,188 125,024,256 94166-161 Wren3 ESDI 969 8 36 279,072 142,884,864 ÚDrive Selects ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ 12 G G 5 1 2 3 4 5 6 7 ³ Term 1³ ÚÄÄÄÄÄÄÄÄÄ¿ o o o o o o o ³ 14 pin dip ³ ÚCommand Cable ³ 0 0 0 0 ³ Power o o o o o o o ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÙÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿1 \ÄÄÄÄÄÄÄÄÄ/ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÚÄÄÄÄÄÄÄÄÄÄ¿1 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍ ÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÀÄÄÄÄÄÄÄÄÄÄÙ ÀData Cable ÚÄ Motor Start option enable ³ | SW1 (located at front of drive behind the B/Sec ³ Sectors ³ 1 2 3 4 front plate) ÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍØÍMÍÍÍÍÍÍ 512 ³ 34 ³ 1 1 0 1=on; 0=off 512 ³ 35 ³ 1 0 0 512 ³ 36 ³ 0 1 0 256 ³ 64 ³ 0 0 0 ³ Add Mark ³ 1 1 1 =========================================================================== 94171-xxx (Wren 4) SCSI Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94171-300 Wren4 SCSI 1412 9 ZBR 586,763 300,422,656 94171-307 Wren4 SCSI 1412 9 ZBR 586,763 300,422,656 94171-327 Wren4 SCSI 1412 9 ZBR 586,763 300,422,656 94171-344 Wren4 SCSI 1549 9 ZBR 631,016 323,080,192 Connects CHASIS ground to ground lug ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ Connects SIGNAL ground to ground lug ÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ Drive Select ID's ÄÄÄÄÄÄÄ¿ ³ ³ Motor Start Option enable ÄÄÄ¿ ³ G G Parity Check Option enable Ä¿ ³ ÚÄÅÄ¿ Ú1Â2¿ P M 4 2 1 ³o³o³ Ú12ÄGÄGÄ5Ä¿ o o o o o ³o³o³ ³ 0 0 0 0 ³ Power o o o o o ÀÄÁÄÙ \ÄÄÄÄÄÄÄÄÄ/ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍServoÍPWAÍ ÍÑÍÍÍÍÍÍÍÑÍÍÍÍÑÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÑÍÍÍÍÍÍÍÍÑÍÍÍÍÍÍÍÍÑÍÍDataÍPWAÍÍ 1ÄÄÄÄÄÄÄÙ ³:::SCSI Cable::::::::::::1 ³ ÚÄ¿ 1ÄÄÄÄÄÄÄÄÙ Terminator DIP ÔÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ; ³o³ o Terminator DIP ³oÅÄo ÀÂÙ Terminator power (+5v) from drive (vertical) ÄÄÄÙ Terminator power from the Bus (lower horizontal) =========================================================================== 94186-xxx (Wren 5) FH ESDI Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94186-265 Wren5 ESDI 1412 9 36 457,488 234,233,856 94186-324 Wren5 ESDI 1412 11 36 559,152 286,285,824 ÚData Cable ÚController Cable /Ä5ÄGÄGÄ12\ ÍÍÍÍÍÍÍÍ ÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍ Í³ 0 0 0 0 ÆÍÍ o o o o o 1ÄÄÄÄÄÄÄÄÄÄÄ¿ o o o o o o o ÀÄÄÄÄÄÄÄÄÄÙ o o o o o ÀTerminatorÄÙ o o o o o o o 1 2 3 4 5 7 6 5 4 3 2 1 Motor Start ÄÄÙ ³ ³ ³ ³ ÀDrive Selects option enable ³ ³ ³ ÀÄ Factory use Note: There are 2 types of PWA's. ³ ³ ³ only One with drive select header on the Sectors ³ ³ ³ left, and one with header on the ÍÍÍÍÍÍÍÍÍÍÍØÍØÍØÍÍ right (like this). Pin positions 64 0 0 0 are the same. 35 0 0 1 10 0 1 0 0=open; 1=closed 19 0 1 1 36 1 0 0 34 1 0 1 87 1 1 0 Add Mark 1 1 1 =========================================================================== 94204-xx (Wren 2) HH AT Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94204-65 Wren2 AT 949 5 ÚÄÄ Master on /Slave off ³ ³ Factory Ú12ÄGÄGÄ5Ä¿ Power AT Cable Connector ³ 1 J2 ³ 0 0 0 0 ³ 1::::::::ù:::::::::: :: ::::::::: \Ä1Ä2Ä3Ä4Ä/ ÍÍÍÍÍÍÍÍÍÍÑÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ pin-20 key ³ ³ ³ For "non-C" model, jumper, if present, ³ ³ must remain on. Drive will not operate ÀÄÄ´ properly if jumper is removed (or added ³ if not originally there). ³ ³ For "C" model, jumper on indicates No ³ Slave Present; jumper off means Slave ³ Drive Is Present. ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ =========================================================================== 94205-xx (Wren 2) HH ST412 MFM Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94205-30 Wren2 ST412 989 3 17 50,439 25,824,768 94205-41 Wren2 ST412 989 4 17 67,252 34,433,024 94205-53 Wren2 ST412 1024 5 17 87,040 44,564,480 Drive Select ÚÄÄÄÄÄÄÄÄÄ¿ o o o o o o o 1 Terminator ³ O O O O ³ Power o o o o o o o ÚÄÄÄÄÄÄÄÄÄÄÄÄ¿ \ÄÄÄÄÄÄÄÄÄ/ 1 2 3 4 R r reserved ÀÄÄÄÄÄÄÄÄÄÄÄÄÙ 1 12 G G 5 ÍÍÍÍÍÍÍÍÍÍ ÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ³ ³ ÀÄController Cable ³ ÀÄÄRadial ÀÄÄÄÄÄÄÄÄIf twisted cable, use Drive Select 2 =========================================================================== 94211-xxx (Wren 3) SCSI Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94211-91 Wren3 SCSI 992 5 4 2 1 P Ú12ÄGÄGÄ5Ä¿ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ A B C D E F G H o o o o ³ 0 0 0 0 ³ Power ³:SCSI:Cable::::pin 1³ o o o o o o o o o o o o \Ä1Ä2Ä3Ä4Ä/ ÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÑÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ³ ³ A-B Not used ³ ÀÄ Parity check B-C Terminator power from Bus ÀÄÄÄÄÄ Drive Select ID C-D Terminator power from Drive D-E Not used E-F Not used F-G Continuous test seeks G-H Motor Start option enable =========================================================================== 94221-xxx( Wren 5) HH SCSI Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94221-169 Wren5 SCSI 1310 5 ZBR 310,539 158,995,968 94221-184 Wren5 SCSI Power SCSI Cable 4 2 1 P Ú12ÄGÄGÄ5Ä¿ ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸ A B C D E F G H o o o o ³ 0 0 0 0 ³ ³:::::::::::::::::::1³ o o o o o o o o o o o o \ÄÄÄÄÄÄÄÄÄ/ ÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÏÍÍÍÍÍPÍWÍAÍÍÍÍÍÍÍÍÍÍÍÑÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ³ ³ A-B Not used ³ ÀÄ Parity check B-C Terminator power from Bus ³ C-D Terminator power from Drive ÀÄÄÄÄÄ Drive Select ID D-E Not used (ID 0 for single E-F Not used drive system) F-G Continuous test seeks G-H Motor Start option enable =========================================================================== 94244-xxx (Wren 6) HH AT (IDE) Inter- Total Formatted Model Family face Cyl Hd SPT Sectors Capacity WPC ----------|------|------|-----|---|-----|---------|-------------|---- 94244-164 Wren6 AT 1747 3 54 283,014 144,903,168 94244-219 Wren6 AT 1747 4 54 377,352 193,204,224 94244-502 Wren6 AT ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ /ÄÄÄÄÄÄÄ\ ÍÍ͵1 AT (IDE) Cable ÆÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͵O O O OÆÍÍ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ o o o o o o o ÀÄÄÄÄÄÄÄÙ o o o o o o o 5 G G 12 G F E D C B A A B 0 0 Factory use only 0 1 Drive is Slave, motor start delay 20 sec from master start-up 1 0 Drive is Slave, no motor start delay 1 1 Drive is Master, motor starts at application of DC power C D 0 0 Physical mode 0 1 Translate (logical) mode, sparing scheme is one sector 1 0 Translate (logical) mode, no sparing space allocated 1 1 Factory use only E 0 Slave present, only meaningful on master 1 No Slave present F G x x Factory test, position G may or may not be present by PWA =========================================================================== 94246-xxx (Wren 6) HH ESDI Ú Data Cable Ú Controller Cable /4Ä3Ä2Ä1\ ÍÍÍÍÍÍÍÍ ÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍ͵0 0 0 0ÆÍÍÍ 1ÄÄÄÄÄÄÄÄÄÄÄ¿ o o o o o o o o ÀÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÙ o o o o o o o o 5 G G 12 Terminator 5 4 3 2 1 4 2 1 ³ ³ ³ ³ ³ ÀDrive Selects Motor Start option enable ÄÙ ³ ³ ³ ÀÄ Factory use only ³ ³ ³ B/Sec ³ Sectors ³ ³ ³ ÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÏÍÏÍÏÍ 256 ³ 96 ³ 0 0 0 512 ³ 54 ³ 1 0 0 1=on, 0=off 1024 ³ 15 ³ 0 1 0 ³ Special ³ 1 1 0 512 ³ 53 ³ 0 0 1 512 ³ 51 ³ 1 0 1 1024 ³ 28 ³ 0 1 1 ³ Add/Mark ³ 1 1 1