BROOKTROUT TECHNOLOGY, INC. TRNIC+P24T Card Type T1/Fax card I/O Options PED connector, 15-pin DSX-1 connector, MVIP connector Data Bus 32-bit PCI [Image] CONNECTIONS Function Label Function Label RJ-45 UTP connector PJ301 MVIP connector J401 USER CONFIGURABLE SETTINGS Function Label Position » Clocking signals generated by T1 SW501/1 Off Clocking signals generated by TRNIC SW501/1 On » Super frame mode SW501/2 Off Extended super frame mode SW501/2 On » B8ZS line coding SW501/3 Off AMI line coding SW501/3 On » Factory configured - do not alter SW501/7 Off » Factory configured - do not alter SW501/8 Off » MVIP clock master set to master SW502/3 Off MVIP clock master set to slave SW502/3 On » Loopback mode disabled SW503 Off Loopback mode enabled SW503 On T1 CABLE LENGTH SETTTINGS Cable Length SW501/4 SW501/5 SW501/6 » 0 to 132 ft. On On On 133 to 266 Off On On ft. 267 to 398 On Off On ft. 399 to 532 Off Off On ft. 533 to 654 On On Off ft. MVIP STREAM SELECT Mode SW502/1 SW502/2 » 6/7 Off Off 4/5 On Off 2/3 Off On 0/1 On On SYNC SOURCE CONTROL Setting SW502/3 SW502/4 » TRNIC controls Off Off Secondary net card Off On controls FRAMING SIGNAL OUTPUT Setting SW502/3 SW502/4 Disable output On Off Enable output On On TERMINATION Setting SW502/5 SW502/6 » Unterminated Off Off Terminated On On DIAGNOSTIC LED(S) LED Color Status Condition D1 Red On Card in network loopback mode D2 Red On T1 signal lost D3 Yellow On Not synchronized on T1 signal D4 Green On Operating in normal mode FRM Unidentified On T1 framing error BPV Unidentified On T1 bipolar violation CRC Unidentified On Discrepancy in cyclic redundancy check