WISECOM, INC. WS-5614JS3/ES3 (INTERNAL) Card Type Modem Chip Set Unidentified I/O Options Line out, line in, speaker out, microphone in Maximum Modem Rate 56Kbps Maximum Fax Rate 14.4Kbps Data Modulation Protocol Bell 103/212A ITU-T V.22, V.22bis, V.32, V.32bis, V.34, 56Kflex Fax Modulation Protocol ITU-T V.17, V.21 CH.2, V.27ter, V.29 Error Correction/Compression MNP5, V.42, V.42bis Fax Class Class I Data Bus 8-bit ISA [Image] CONNECTIONS Function Label Function Label Line out (RJ-11) CN1 Speaker out CN3 Line in (RJ-11) CN2 Microphone in CN4 PLUG & PLAY Setting JP3 JP4 ? Plug & play enabled Pins 1 & 2 closed Pins 1 & 2 closed Plug & play disabled Pins 2 & 3 closed Pins 2 & 3 closed SERIAL PORT ADDRESS Setting SW1/1 SW1/2 COM1 (3F8h) On On COM2 (2F8h) Off On COM3 (3E8h) On Off COM4 (2E8h) Off Off INTERRUPT IRQ SW1/3 SW1/4 SW1/5 SW1/6 2 On Off Off Off 3 Off On Off Off 4 Off Off On Off 5 Off Off Off On SUPPORTED COMMAND SET Basic AT Commands AT, ‘+++’, A/ A, B, E, H, V &C, &M, &P, &T, &V, &W, &X, &Y, &Z Extended AT Commands %C, %E, %L, %Q \A, \B, \K, \N Special Commands S Registers S0, S1, S2, S3, S4, S5, S6, S7, S8, S9,S10, S11, S12, S14, S16, S18, S21, S22, S23, S24, S25 S26, S27, S29, S30, S31, S32, S33, S36, S37, S38, S39, S40, S41, S46, S48, S82, S91, S92, S95 Note: See MHI Help File for full command documentation. PROPRIETARY AT COMMAND SET COMMUNICATIONS MODE Type: Configuration Format: AT [cmds] &Qn [cmds] Description: Selects communications mode options Command Mode &Q0 Asynchronous mode, serial port speed follows connect speed. &Q1 Asynchronous off-line command mode and synchronous connect mode. &Q2 Asynchronous off-line command mode - modem autodials first number in directory, then synchronous connect mode. &Q3 Asynchronous off-line command mode on low DTR, synchronous connect mode on high DTR. ? &Q5 Error correction mode &Q6 Buffered asynchronous mode DATA SET READY (DSR) Type: Configuration Format: AT [cmds] &Sn [cmds] Description: Selects DSR options Command Function &S0 DSR forced high &S1 DSR high only while modem is handshaking or connected DATA TERMINAL READY (DTR) Type: Configuration Format: AT [cmds] &Dn [cmds] Description: Selects modem response to DTR Command Mode &D0 DTR ignored &D1 DTR toggle causes online command mode ? &D2 DTR toggle causes modem to go on-hook &D3 Modem reset on DTR toggle DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string FACTORY DEFAULT PROFILE Type: Configuration Format: AT [cmds] &F [cmds] Description: Sets values in active profile to values found in the default profile &F0 Load factory configuration 0 &F1 Load factory configuration 1 FLOW CONTROL Type: Configuration Format: AT [cmds] &Kn [cmds] Description: Enables flow control options Command Function &K0 Flow control disabled &K3 RTS/CTS flow control enabled &K4 XON/XOFF flow control enabled &K5 Transparent XON/XOFF flow control enabled ? &K6 Both RTS/CTS & XON/XOFF flow control enabled GUARD TONE Type: Configuration Format: AT [cmds] &Gn [cmds] Description: Commands the modem to transmit a guard tone in V.22/V.22bis Note: Used primarily for international data transmission Command Function ? &G0 Guard tone disabled &G1 550Hz guard tone enabled &G2 1800Hz guard tone enabled REPORT INFORMATION Type: Immediate Format: AT [cmds] In [cmds] Description: Displays information requested Command Function I0 Reports modem model and speed I1 Reports ROM checksum I2 Tests and reports ROM checksum I3 Reports product ID string I6 Reports diagnostic information I7 Reports product configuration RESTORE PROFILE ON POWER-UP Type: Configuration Format: AT [cmds] Yn [cmds] Description: Restores a selected profile to default profile on power-up (hard reset) Command Function ? Y0 Restore stored profile 0 on power-up Y1 Restore stored profile 1 on power-up Y2 Load factory default configuration 0 on power-up Y3 Load factory default configuration 1 on power-up Y4 Load factory default configuration 2 on power-up RTS/CTS Type: Configuration Format: AT [cmds] &Rn [cmds] Description: Selects RTS/CTS options Command Function &R0 CTS follows RTS in data mode; RTS is ignored in command mode. ? &R1 CTS forced high, RTS is ignored. SOFT RESET Type: Configuration Format: AT [cmds] Zn [cmds] Description: Restores modem profiles previously stored in non-volatile RAM using the &W command Command Function ? Z1 Restore stored profile 0 Z2 Restore stored profile 1 Z3 Load factory default configuration 0 Z4 Load factory default configuration 1 Z5 Load factory default configuration 2 SPEAKER MODE Type: Configuration Format: AT [cmds] Mn [cmds] Description: Selects various speaker options Command Function M0 Speaker disabled M1 Speaker enabled until carrier signal detected SPEAKER VOLUME Type: Configuration Format: AT [cmds] Ln [cmds] Description: Controls speaker volume Command Function L0 Low volume setting L1 Low volume setting ? L2 Medium volume setting L3 Highest volume setting EXTENDED AT COMMAND SET MODULATION SELECTION Type: Configuration Format: AT [cmds] +MS=x,y,z,a,b,c [cmds] Description: Sets options for active protocol; the transfer rates specified by z and a must be valid for the protocol selected. Command Function x=0 V.21 x=1 V.22 x=2 V.22bis x=3 V.23 x=9 V.32 x=10 V.32bis x=11 V.34, K56flex x=64 Bell 103 x=69 Bell 212A y=0 Automode disabled y=1 Auto-detect highest speed enabled z, a=300 Set minimum or maximum transfer rate at 300bps, respectively. z, a=1200 Set minimum or maximum transfer rate at 1200bps, respectively. z, a=2400 Set minimum or maximum transfer rate at 2400bps, respectively. z, a=4800 Set minimum or maximum transfer rate at 4800bps, respectively. z, a=7200 Set minimum or maximum transfer rate at 7200bps, respectively. z, a=9600 Set minimum or maximum transfer rate at 9600bps, respectively. z, a=12000 Set minimum or maximum transfer rate at 12000bps, respectively. z, a=14400 Set minimum or maximum transfer rate at 14400bps, respectively. z, a=16800 Set minimum or maximum transfer rate at 16800bps, respectively. z, a=19200 Set minimum or maximum transfer rate at 19200bps, respectively. z, a=21600 Set minimum or maximum transfer rate at 21600bps, respectively. z, a=24000 Set minimum or maximum transfer rate at 24000bps, respectively. z, a=26400 Set minimum or maximum transfer rate at 26400bps, respectively. z, a=28800 Set minimum or maximum transfer rate at 28800bps, respectively. z, a=33600 Set minimum or maximum transfer rate at 33600bps, respectively. b=0 m -law encoding b=1 A -law encoding c=0 Robbed bit signaling disabled c=1 Robbed bit signaling enabled S(Status) REGISTERS CONNECTION FAILURE CODES Type: Register Format AT [cmds] S86? [cmds] Description: Reports codes which correspond to the possible causes of a connection failure Value Meaning 0 Normal hang up 4 Carrier signal lost 5 No error-control detected for remote modem during feature negotiation 9 No common protocol found 12 No failure - remote modem disconnected normally 13 Remote modem failed to respond after 10 re-transmissions same message 14 Violation of negotiated protocol caused failure