WESTERMO TELEINDUSTRI AB LD-01 Card Type Modem Chip Set Unidentified I/O Options 9-pin serial port (RS-232), terminal blocks (3) Data Modulation Protocol ITU-T V.24/V.28 Wiring Type Unshielded twisted pair Maximum Data Rate 38.4Kbps Data Bus External [Image] CONNECTIONS Function Label Function Label 9-pin DCE serial port - channel 1 CN1 DCE serial port - channel 4 CN4 DCE serial port - channel 2 (5 pole terminal CN2 AC power (3 pole terminal CN5 block) block) DCE serial port - channel 3 CN3 Note: CN3 & CN4 are separate serial interfaces on a 9 pole terminal block USER CONFIGURABLE SETTINGS Function Label Position 10mA balance current loop enabled on J1 Pins 2 & 3 channel 2 closed RS-232-C/V.24 interface enabled on channel J1 Pins 1 & 2 2 closed 10mA balance current loop enabled on J2 Pins 2 & 3 channel 3 closed RS-232-C/V.24 interface enabled on channel J2 Pins 1 & 2 3 closed Factory configured - do not alter S1/3 Off Factory configured - do not alter S1/4 Off MASTER/SLAVE CONFIGURATION Setting S1/1 S1/2 Communication between all units enabled On On Communication between masters and slaves Off Off enabled DIAGNOSTIC LED(S) LED Color Status Condition PWR Unidentified On Power is on PWR Unidentified Off Power is off RD Unidentified On Modem is receiving data RD Unidentified Off Modem is not receiving data TD Unidentified On Modem is transmitting data TD Unidentified Off Modem is not transmitting data DCD2 Unidentified On Data carrier present on channel 2 DCD2 Unidentified Off Data carrier not present. Connection not established on channel 2 DCD3 Unidentified On Data carrier present on channel 3 DCD3 Unidentified Off Data carrier not present. Connection not established on channel 3 DCD4 Unidentified On Data carrier present on channel 4 DCD4 Unidentified Off Data carrier not present. Connection not established on channel 4