WESTERMO TELEINDUSTRI AB MA-12 Card Type Modem Chip Set Unidentified I/O Options AC power, 25-pin serial port, network interface via terminal block Data Modulation Protocol ITU-T V.24/V.28 Wiring Type Unshielded twisted pair Maximum Data Rate 38.4Kbps Data Bus External [Image] CONNECTIONS Function Label Function Label AC power CN1 25-pin serial port CN3 UTP interface (terminal CN2 block) USER CONFIGURABLE SETTINGS Setting Label Position 115V AC enabled S2 On 230V AC enabled S2 Off CARRIER CONTROL Setting S1/1 S1/2 S1/3 S1/4 S1/5 S1/6 Carrier forced high Off On Off Off Off Off Carrier activated by Off On On Off Off Off AUX Carrier activated by Off On Off On Off Off SRS Carrier activated by Off On Off Off On Off RFR Carrier activated by Off On Off Off Off On RTS Carrier activated by On Off Off Off Off Off DTR Carrier activated by On Off On Off Off Off DTR and AUX Carrier activated by On Off Off On Off Off DTR and SRS Carrier activated by On Off Off Off On Off DTR and RFR Carrier activated by On Off Off Off Off On DTR and RTS CLEAR TO SEND CONTROL Setting S1/7 S1/8 S1/9 CTS controlled by RTS On Off Off CTS forced high Off On Off CTS follows DCD Off Off On DIAGNOSTIC LED(S) LED Color Status Condition PWR Unidentified On Power is on PWR Unidentified Off Power is off RD Unidentified On Modem is receiving data RD Unidentified Off Modem is not receiving data TD Unidentified On Modem is transmitting data TD Unidentified Off Modem is not transmitting data RTS Unidentified On RTS signal is high RTS Unidentified Off RTS signal is low DCD Unidentified On Data carrier present DCD Unidentified Off Data carrier not present. Connection not established