PATTON ELECTRONICS COMPANY 2710 Card Type T1 CSU/DSU Chip Set Unidentified I/O Options V.35 DTE/DCE port, power, network interface via RJ-48 T1 Transfer Rate 1.544Mbps T1 Protocol AMI, B8ZS Frame type D4, ESF Data Bus External [Image] CONNECTIONS Function Label Function Label V.35 DTE/DCE serial port CN1 DC power CN3 (34-pin male connector) Network interface via RJ-48 CN2 connector USER CONFIGURABLE SETTINGS Setting Label Position » ESF/B8ZS framing and coding SW1/4 Off enabled D4/AMI framing and coding enabled SW1/4 On » 64Kbps DSO rate SW1/5 On 56Kbps DSO rate SW1/5 Off » Transmit clock derived from SW1/6 Off receive line signal Transmit clock generated SW1/6 On internally » Power supplied via DC power jack JP1 Pins 2 & 4 closed Power supplied to pin KK on V.35 JP1 Pins 1 & 2 connector closed DATA RATE n x56 n x64 SW1/1 SW1/2 SW1/3 Clear channel Off Off Off (unframed) 112Kbps 128Kbps On Off Off 224Kbps 256Kbps Off On Off 336Kbps 384Kbps On On Off 448Kbps 512Kbps Off Off On 672Kbps 768Kbps On Off On 896Kbps 1.024Mbps Off On On » 1.344Mbps 1.536Mbps On On On LINE BUILD Net build SW1/7 SW1/8 » 0dB Off Off -7.5dB On Off -15dB Off On -22.5dB On On DIAGNOSTIC LED(S) LED Color Status Condition TXD Green On DTE is transmitting data to CSU/DSU TXD Green Off DTE is not transmitting data to CSU/DSU RXD Green On DTE is receiving data from CSU/DSU RXD Green Off DTE is not receiving data from CSU/DSU LOS Red On Loss of signal or loss of frame condition detected on network LOS Red Off Loss of signal or loss of frame condition not detected on network ALM Red On Alarm condition detected on network ALM Red Off Alarm condition not detected on network ERR Red On Error second (ES) detected on received configuration information ERR Red Off Error second (ES) not detected on received configuration information TST Yellow On Device is conducting a loopback test TST Yellow Off Device is not conducting a loopback test PWR Green On Power is on PWR Green Off Power is off