ARCHTEK CORPORATION 5634BTS Card Type Modem/Fax card Chip Set Texas Instruments Maximum Modem Rate 56Kbps Maximum Fax Rate 14.4Kbps Data Modulation Protocol Bell 103/212Z ITU-T V.21, V.22, V.22bis, V.32, V.32bis, V.34, V.34bis, V.90, X2 Fax Modulation Protocol ITU-T V.17, V.27ter, V.29, V.21 CH 2 Error Correction/Compression MNP5, V.42, V.42bis Fax Class Class I & 2 Data Bus 16-bit ISA [Image] CONNECTIONS Function Label Function Label Line in (RJ-11) CN1 Speaker jack CN3 Line out (RJ-11) CN2 Microphone jack CN4 SERIAL PORT ADDRESS Setting JP1/A JP1/B JP1/C COM1 (3F8h) Closed Closed Closed COM2 (2F8h) Open Closed Closed COM3 (3E8h) Closed Open Closed COM4 (2E8h) Open Open Closed Plug & play Open Open Open INTERRUPT Setting JP2/A JP2/B JP2/C JP2/D JP2/E JP2/F IRQ3 Closed Open Open Open Open Open IRQ4 Open Closed Open Open Open Open IRQ5 Open Open Closed Open Open Open IRQ9 Open Open Open Closed Open Open IRQ10 Open Open Open Open Closed Open IRQ15 Open Open Open Open Open Closed Plug & play Open Open Open Open Open Open SUPPORTED COMMAND SET Basic AT Commands AT, ‘+++’, A/ A, E, H, M, O, V &C, &G, &T, &W, &Z S Registers S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S18 Note: See MHI Help File for full command documentation. PROPRIETARY AT COMMAND SET BREAK OPTIONS Type: Configuration Format AT [cmds] &Yn [cmds] Description: Sets the method for break transmission during error-control and ASB connections. Command Function &Y0 Destructive signaling, buffers cleared, does not pass break to DCE &Y1 Expedited destructive signaling, buffers cleared, immediately send timed break &Y2 Expedited signaling, break sent out of sequence COMMUNICATION PROTOCOLS Type: Configuration Format: AT [cmds] Bn [cmds] Description: Selects the communication protocol for data calls Command Protocol B0 ITU-T V.25 answer sequence B1 Answer tone COMPRESSION Type: Configuration Format: AT [cmds] &Kn [cmds] Description: Selects data compression Command Function &K0 Data compression disabled &K1 MNP5 and V.42bis enabled if DTE rate is higher than link rate and data compression supported by remote &K2 MNP5 and V.42bis enabled &K3 V.42bis enabled CONNECT MODE Type: Configuration Format: AT [cmds] &Mn [cmds] Description: Controls the type of connection the modem will operate in Command Function &M0 Normal mode enabled &M4 Auto-reliable mode enabled &M5 MNP reliable mode enabled DATA SET READY (DSR) Type: Configuration Format: AT [cmds] &Sn [cmds] Description: Selects DSR options Command Function &S0 DSR forced high &S1 DSR high only while modem is handshaking or connected DATA TERMINAL READY (DTR) Type: Configuration Format: AT [cmds] &Dn [cmds] Description: Selects modem response to DTR Command Function &D0 DTR override &D1 DTR toggle causes online command mode &D2 DTR toggle causes modem to go on-hook DCE LINE SPEED (MAXIMUM) Type: Configuration Format AT [cmds] &Nn [cmds] Description: Sets the maximum allowable data exchange rate attempted during handshake process. Command Function &N1 Speed of last connection &N2 300bps &N3 1200bps &N4 2400bps &N5 4800bps &N6 7200bps &N7 9600bps &N8 12.0Kbps &N9 14.4Kbps &N10 16.8Kbps &N22 19.2Kbps &N12 21.6Kbps &N13 24.0Kbps &N14 26.4Kbps &N15 28.8Kbps &N16 31.2Kbps &N17 33.6Kbps &N18 32.0Kbps (X2) &N19 36.0Kbps (X2) &N20 40.0Kbps (X2) &N21 44.0Kbps (X2) &N22 48.0Kbps (X2) &N23 49.3Kbps (X2) &N24 50.7Kbps (X2) &N25 52.0Kbps (X2) &N26 53.3Kbps (X2) &N27 54.7Kbps (X2) &N256.0Kbps (X2) &N29 57.3Kbps (X2) &N30 58.7Kbps (X2) &N360.0Kbps (X2) &N32 61.3Kbps (X2) DCE LINE SPEED (MINIMUM) Type: Configuration Format AT [cmds] &Un [cmds] Description: Sets the minimum allowable data exchange rate attempted during handshake process. Command Function &U1 No minimum &U2 300bps &U3 1200bps &U4 2400bps &U5 4800bps &U6 7200bps &U7 9600bps &U8 12.0Kbps &U9 14.4Kbps &U10 16.8Kbps &U22 19.2Kbps &U12 21.6Kbps &U13 24.0Kbps &U14 26.4Kbps &U15 28.8Kbps &U16 31.2Kbps &U17 33.6Kbps &U18 32.0Kbps (X2) &U19 36.0Kbps (X2) &U20 40.0Kbps (X2) &U21 44.0Kbps (X2) &U22 48.0Kbps (X2) &U23 49.3Kbps (X2) &U24 50.7Kbps (X2) &U25 52.0Kbps (X2) &U26 53.3Kbps (X2) &U27 54.7Kbps (X2) &U256.0Kbps (X2) &U29 57.3Kbps (X2) &U30 58.7Kbps (X2) &U360.0Kbps (X2) &U32 61.3Kbps (X2) DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string Note: Any combination of modifiers can be used to produce the desired dial functions in sequence. Command Function DL Re-dial last number DP Pulse dialing enabled DT Tone dialing enabled/Pulse dialing disabled DW Dialing resumed following dial tone detection D, Dialing paused for amount of time specified in S8 register D! Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. D/ Delays for 125ms before dialing DR Answer mode enabled; originate mode disabled following handshake initiation. DSn Dial stored telephone number n D@ Wait for Quite Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. D$ Wait for prompt tone detection function enabled. Waits for prompt tone for amount of time specified by the S7 command. D; Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. ERROR CORRECTION RESULT CODES Type: Configuration Format: AT [cmds] &An [cmds] Description: Selects error correction responses Command Function &A0 ARQ result codes disabled &A1 ARQ to word CONNECT result codes enabled when an error correction connection is made &A2 V.32 indicator added in result codes for calls at or above 4800bps &A3 Protocol response added: /LAPM, /MNP, or NONE and V.42bis/MNP5 FACTORY DEFAULT PROFILE Type: Configuration Format: AT [cmds] &Fn [cmds] Description: Sets values in active profile to values found in the default profile Command Function &F0 Load standard factory configuration &F1 Restore factory configuration 1. Hardware flow control &F2 Restore factory configuration 2. Software flow control FLOW CONTROL Type: Configuration Format: AT [cmds] &Hn [cmds] Description: Enables flow control options Command Function &H0 Flow control disabled &H1 RTS to CTS flow control enabled &H2 XON/XOFF flow control enabled &H3 RTS/CTS & XON/XOFF flow control enabled LIST DISPLAY Type: Immediate Format: AT [cmds] &$ [cmds] Description: Displays a list of ampersand commands LOCK SERIAL PORT Type: Configuration Format: AT [cmds] &Bn [cmds] Description: Sets operation of serial port speed Command Function &B0 Serial speed follows connect speed &B1 Serial speed locked &B2 In answer mode; serial speed fixed for ARQ calls, variable for non-ARQ calls PULSE DIALING RATIO Type: Configuration Format: AT [cmds] &Pn [cmds] Description: Selects pulse dial make/break ratio Command Function &P0 39/61ms at 10pps (North America) &P1 33/67ms at 10pps (Europe) REPORT INFORMATION Type: Immediate Format: AT [cmds] In [cmds] Description: Displays information requested Command Function I0 Reports product code I1 Reports ROM checksum I2 Reports results of RAM self-test I3 Reports product type I4 Reports current modem settings I5 Reports NVRAM settings I6 Reports link diagnostics I7 Reports product confirmation I8 Reserved I9 Reports plug & play information I10 Reserved I11 Reports call statistics RESTORE PROFILE ON POWER-UP Type: Configuration Format: AT [cmds] Yn [cmds] Description: Restores a selected profile into the active profile on power-up (hard reset) Command Function Y0 Restore profile 0 on power-up Y1 Restore profile 1 on power-up Y2 Restore generic factory template (&F0) Y3 Hardware flow control (&F1) Y4 Software flow control (&F2) RESULT CODES Type: Configuration Format: AT [cmds] Qn [cmds] Description: Enables modem to send result codes to the DTE Command Function Q0 Result code sending enabled Q1 Result code sending disabled Q2 Result code sending only in originate mode Q3 Result code sending only in ring mode RTS Type: Configuration Format: AT [cmds] &Rn [cmds] Description: Selects RTS Command Function &R0 RTS signal is ignored &R1 Data is sent to DTE only is RTS in forced high SELECT CALL PROGRESS RESULT CODES Type: Configuration Format: AT [cmds] Xn [cmds] Description: Enables selection of tone detection and associated result code format options Command Function X0 Busy and dial tone detection disabled; result codes 0 - 4 enabled. X1 Busy and dial tone detection disabled; result codes 0 - 5 & 10 - 25 enabled. X2 Busy tone detection disabled, dial tone detection enabled; result codes 0 - 6 & 10 - 236 enabled. X3 Busy and dial tone detection disabled; 8 - 236 enabled. X4 - X6 Busy and dial tone detection enabled; extended result codes enabled SOFT RESET Type: Immediate Format: AT [cmds] Zn [cmds] Description: Restores modem profiles previously saved in non-volatile RAM using the &W command. Command Function Z0 Restore NVRAM profile selected by ATY command Z1 Restore NVRAM profile 0 Z2 Restore NVRAM profile 1 Z3 Restore factory default profile 0 (&F0) Z4 Restore factory default profile 1 (&F1) Z5 Restore factory default profile 2 (&F2) SPEAKER VOLUME Type: Configuration Format: AT [cmds] Ln [cmds] Description: Controls speaker volume Command Function L0 Low volume setting L1 Low volume setting L2 Medium volume setting L3 Highest volume setting XON/XOFF PASS-THROUGH Type: Configuration Format: AT [cmds] &In [cmds] Description: Selects whether XON/XOFF signals are sent to remote modem Command Function &I0 XON/XOFF signals trapped by local modem &I1 XON/XOFF passed through local modem and remote &I2 XON/XOFF passed through local modem only S(status) -REGISTERS ANSWER TONES, DEFAULT TIMES, AND CONNECTION LIMITING Type: Register Format AT [cmds] S28=n [cmds] Description: Controls answer tones, connections, and time specified Command Function S28=0 Eliminates V.32 answer tones for a faster connection S28=8 All default times are in 1sec units S28=255 Connections disabled except V.32 9600bps BIT-MAPPED REGISTER S27 Format: AT [cmds] S27=n [cmds] Range: 0-255 Description: Select modulations and error correction flags Bit Value Function 0 0 V.21/Bell 103 mode disabled 1 V.21/Bell 103 mode enabled 1 0 Unencoded modulation in V.32 mode disabled 1 Unencoded modulation in V.32 mode enabled 2 0 V.32 modulation enabled 1 V.32 modulation disabled 3 0 2100Hz answer tone enabled 1 2100Hz answer tone enabled 4 0 V.23 fallback mode disabled 1 V.23 fallback mode enabled 5 0 V.32bis mode enabled 1 V.32bis mode disabled 6 0 Reserved 7 0 Software compatibility mode disabled 1 Software compatibility mode enabled BIT-MAPPED REGISTER S32 Format: AT [cmds] S32=n [cmds] Range: 0-255 Description: Select modulations and call control flags Bit Value Function 0 0 V.8 call indicate disabled 1 V.8 call indicate enabled 1 0 V.8 mode disabled 1 V.8 mode enabled 2 0 V.FC modulation enabled 1 V.FC modulation disabled 3 0 V.34 modulation enabled 1 V.34 modulation disabled 4 0 V.34+ modulation enabled 1 V.34+ modulation disabled 5 0 X2 modulation enabled 1 X2 modulation disabled 6 0 V.90 modulation enabled 1 V.90 modulation disabled 7 0 Reserved BIT-MAPPED REGISTER S33 Format: AT [cmds] S33=n [cmds] Range: 0-255 Description: Enables/disables symbol rates Bit Value Function 0 0 2400 symbol rate enabled 1 2400 symbol rate disabled 1 0 2743 symbol rate enabled 1 2743 symbol rate disabled 2 0 2800 symbol rate enabled 1 2800 symbol rate disabled 3 0 3000 symbol rate enabled 1 3000 symbol rate disabled 4 0 3200 symbol rate enabled 1 3200 symbol rate disabled 5 0 3429 symbol rate enabled 1 3429 symbol rate disabled 6 0 Reserved 7 0 2400 symbol rate enabled 1 2400 symbol rate disabled BIT-MAPPED REGISTER S34 Format: AT [cmds] S34=n [cmds] Range: 0-255 Description: Controls trellis coding options Bit Value Function 0 0 8S-2D trellis encoding enabled 1 8S-2D trellis encoding disabled 1 0 16S-4D trellis encoding enabled 1 16S-4D trellis encoding disabled 2 0 32S-2D trellis encoding enabled 1 32S-2D trellis encoding disabled 3 0 64S-4D trellis encoding enabled 1 64S-4D trellis encoding disabled 4 0 Non-linear coding enabled 1 Non-linear coding disabled 5 0 TX level deviation enabled 1 TX level deviation disabled 6 0 Pre-emphasis enabled 1 Pre-emphasis disabled 7 0 Pre-coding enabled 1 Pre-coding disabled BIT-MAPPED REGISTER S41 Format: AT [cmds] S41=n [cmds] Range: 0-255 Description: Controls trellis coding options Bit Value Function 0, 1 0000 Full-duplex speaker mode 0001 Half-duplex speaker mode 1000 Message waiting 7-2 0 Reserved BREAK CHARACTER LENGTH Type: Register Format AT [cmds] S21=n [cmds] Range: 0-255 Unit: 10ms Description: Sets the length of break characters sent from modem to DTE in MNP or V.42 mode DCE LINE SPEED (PARTIALLY BIT-MAPPED) Type: Register Format AT [cmds] S35=n [cmds] Description: Sets the maximum allowable data exchange rate attempted during handshake process and limits x2 back channel operation Command Function S35=0 No back channel rate S35=1 28.8Kbps S35=2 26.4Kbps S35=3 24.0Kbps S35=4 21.6Kbps S35=5 19.2Kbps S35=6 16.8Kbps S35=7 14.4Kbps Bit Value Function 3 0 X2 server operation disabled 1 X2 server operation enabled 4 0 A /m law operation disabled 1 A /m law operation enabled 5 0 A /m law detection enabled 1 A /m law detection disabled 6 0 Reduced power enabled 1 Reduced power disabled 7 0 Reserved DTR IGNORE TIME ON CONNECT Type: Register Format AT [cmds] S25=n [cmds] Range: 0-255 Unit: .01 second Description: Sets time modem waits to hang-up when DTR signal shuts off Note: This is the function of this register when &D2 is set. FLOW CONTROL CHARACTER - XOFF Type: Register Format: AT [cmds] S23=n [cmds] Range: 0-255 Unit: ASCII Description: Sets the character used to represent XOFF FLOW CONTROL CHARACTER - XON Type: Register Format: AT [cmds] S22=n [cmds] Range: 0-255 Unit: ASCII Description: Sets the character used to represent XON INACTIVITY TIMER Type: Register Format AT [cmds] S19=n [cmds] Range: 0-255 Unit: 1min Description: Maximum duration of DTE and DCE inactivity allowed prior to initiating hang-up process. Note: S19=0 disables the timer and allows indefinite inactivity.