RAD DATA COMMUNICATIONS ACE-20-T1 Card Type ATM Access Concentrator NIC Type T1, ISDN Chip Set Unidentified I/O Options AC power connector, DTE/DCE ports (2), alarm relay terminal block 9-pin serial port(2), T1 network interface via RJ-48 connectors (2) Wiring Type T1 T1 Transfer Protocol 1.544Mbps Frame Type ESF, SF Frame Relay ATM PVC T1 Protocol AMI, B7ZS, B8ZS Data Bus External [Image] CONNECTIONS Function Label Function Label AC power connector CN1 Main T1 network port CN6 (RJ-48 connector) Alarm relay terminal CN2 DTE serial port CN7 block Sub T1 network port CN3 DCE serial port CN8 (RJ-48 connector) Channel 1 port (15-pin CN4 Power switch SW2 connector) Channel 2 port (25-pin CN5 connector) Note: Channel 1 and 2 data ports may have different interfaces than pictured above. Data port options include any combination of the following: 15-pin connector for X.21 interface, 25-pin connector for RS-530 interface, or 34-pin connector for V.35 interface USER CONFIGURABLE SETTINGS Setting Label Position DCE timing enabled on port 1 JP1 Pins 2 & 3 closed DTE timing enabled on port 1 JP1 Pins 1 & 2 closed DCE timing enabled on port 2 JP2 Pins 2 & 3 closed DTE timing enabled on port 2 JP2 Pins 1 & 2 closed Signal ground is connected to the JP3 Pins 1 & 2 closed frame ground Signal ground is not connected to JP3 Pins 2 & 3 closed the frame ground Local software download enabled S1/1 On Local software download disabled S1/1 Off Data base initialization enabled S1/2 On Data base initialization disabled S1/2 Off Password enabled S1/3 On Password disabled S1/3 Off » Factory configured - do not alter S1/4 Unidentified » Factory configured - do not alter S1/5 Unidentified » Factory configured - do not alter S1/6 Unidentified DIAGNOSTIC LEDS LED Color Status Condition RED 1 Unidentified On Device is detecting a red alarm condition on the main link RED 1 Unidentified Off Device is not detecting a red alarm condition on the main link YEL 1 Unidentified On Device is detecting a yellow alarm condition on the main link YEL 1 Unidentified Off Device is not detecting a yellow alarm condition on the main link RED 2 Unidentified On Device is detecting a red alarm condition on the sub link RED 2 Unidentified Off Device is not detecting a red alarm condition on the sub link YEL 2 Unidentified On Device is detecting a yellow alarm condition on the sub link YEL 2 Unidentified Off Device is not detecting a yellow alarm condition on the sub link TD1 Unidentified On Device is transmitting data on channel 1 TD1 Unidentified Off Device is not transmitting data on channel 1 RD1 Unidentified On Device is receiving data on channel 1 RD1 Unidentified Off Device is not receiving data on channel 1 TD2 Unidentified On Device is transmitting data on channel 2 TD2 Unidentified Off Device is not transmitting data on channel 2 RD2 Unidentified On Device is receiving data on channel 2 RD2 Unidentified Off Device is not receiving data on channel 2 ALRM Unidentified On Alarms are stored in alarm buffer ALRM Unidentified Off Alarms are not stored in alarm buffer TUnidentified On Device is conducting a loopback test TEST Unidentified Off Device is not conducting a loopback test