PATTON ELECTRONICS COMPANY 1094 Card Type Modem Chip Set Unidentified I/O Options AC power connector, DTE/DCE serial port, network interface via RJ-45 connector Wiring Type RJ-45 shielded twisted pair Maximum Data Rate 768Kbps (synchronous) Data Bus External [Image] CONNECTIONS Function Label Function Label AC power connector CN1 Network interface via RJ-45 CN3 connector DTE/DCE port (quick connect CN2 Power switch SW3 module) Note: Quick connect serial interface module can be configured as a V.24/RS-232, V.35, RS422/530, or X.21 port USER CONFIGURABLE SETTINGS Setting Label Position Carrier forced high S1/5 Off Carrier controlled by RTS S1/5 On Modem ignores requests from DTE S1/6 Off Modem responds to remote digital loopback S1/6 On requests from DTE Modem ignores requests from DTE S1/7 Off Modem responds to local analog loopback S1/7 On requests from DTE Modem responds to V.54 sequence S1/8 Off Modem ignores V.54 sequence S1/8 On TRANSMIT CLOCK SOURCE Source S1/1 S1/2 Transmit clock generated internally On On Receive recover clock source On Off Transmit clock generated externally Off On Note: When X.21 module is installed, one base unit must be configured to receive recover clock source RTS/CTS DELAY Source S1/3 S1/4 Short delay (1-4ms) between RTS and On On CTS activation No delay between RTS and CTS On Off activation Long delay (8-20ms) between RTS and Off On CTS activation No delay between RTS and CTS Off Off activation DATA RATE Setting S2/1 S2/2 S2/3 S2/4 384Kbps Off On On On 768Kbps On Off Off Off LOOPBACK TEST SELECTOR Function Label Position Activates local analog loopback SW4 1 Normal operation. Loopback not activated SW4 2 Remote digital loopback initiated SW4 3 TEST PATTERN GENERATOR Function Label Position 511/E test pattern transmitted SW5 1 (intentional errors inserted) Normal operation. Test pattern not SW5 2 activated 511 test pattern transmitted SW5 3 DIAGNOSTIC LED(S) LED Color Status Condition TD Red On Data is being transmitted (low logic level, device idle) TD Green On Data is being transmitted (high logic level) TD None Off Data is not being transmitted RD Red On Data is being received (low logic level, device idle) RD Green On Data is being received (high logic level) RD None Off Data is not being received RTS Green On RTS signal is high RTS Green Off RTS signal is low CD Green On Carrier signal detected CD Red On Carrier signal not detected DTR Green On DTR signal is high DTR Green Off DTR signal is low ER Red On Bit error likely in received signal or error detected in 511 or 511/E test pattern ER Red On Error not detected TM Green On Device has been placed in test mode by local or remote user TM Green Off Device is not conducting a test