MAXTECH CORPORATION XPV 56I41 (K56PLUS-L/CPI-SVD) Card Type Modem, Fax Chip Set Lucent I/O Options Line in, line out, microphone in, speaker out Maximum Modem Rate 56Kbps Maximum Fax Rate 14.4Kbps Data Modulation Protocol Bell 103/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, K56Plus Fax Modulation Protocol ITU-T V.17, V.29, V.27ter Error Correction/Compression MNP5, V.42, V.42bis Fax Class Class I & II Data Bus 16-bit ISA SUPPORTED COMMAND SET Basic AT Commands AT, ‘+++’, A/ A, E, H, M, O, P, Q, T, V, W, Y, Z &C, &F, &G, &V, &W, &Z Extended AT Commands \A, \B, \J, \K, \T, \X -C S Registers S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S14, S21, S22, S24, S30, S36, S37, S48 Note: See MHI Help File for full command documentation. Proprietary AT Command Set AUTOSCAN MODE Type: Immediate Format: AT [cmds] Nn [cmds] Description: Enables/Disables Autoscan mode Command Function N0 Autoscan mode disabled í N1 Autoscan mode enabled COMMUNICATIONS MODE (ASYNCHRONOUS) Type: Configuration Format: AT [cmds] &Mn [cmds] Description: Selects communications mode Command Mode &M0 Asynchronous mode COMMUNICATIONS MODE (DATA LINK AND FALLBACK) Type: Configuration Format: AT [cmds] &Q [cmds] Description: Configures data link options Command Function &Q0 Set Direct data link only &Q5 Set V.42 data link with fallback options &Q6 Set Normal data link only COMMUNICATION PROTOCOLS Type: Configuration Format: AT [cmds] Bn [cmds] Description: Selects the communication protocol for data calls Note: The B command allows the simultaneous selection of more than one suffix, enabling multiple protocols. Command Protocol B0 Sets CCITT mode í B1 Sets Bell mode B2 CCITT V.23 originate: transmit 75/receive 1200bps B3 CCITT V.23 originate: transmit 1200/receive 75bps B15 Sets V.21 at 300 bps B16 Sets Bell 103 at 300 bps DATA SET READY (DSR) Type: Configuration Format: AT [cmds] &Sn [cmds] Description: Selects DSR options Command Function &S0 DSR forced high &S1 DSR is off while in command mode and set on in on-line mode DATA TERMINAL READY (DTR) Type: Configuration Format: AT [cmds] &Dn [cmds] Description: Selects modem response to DTR Command Function &D0 Modem does not respond to DTR &D1 Modem goes to command mode after DTR goes is off &D2 Modem goes to command mode and disconnects (hangs up) after DTR goes off; Auto-Answer is disabled. &D3 Modem is initialized after DTR goes off DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string Note: Any combination of modifiers can be used to produce the desired dial functions in sequence. Command Function DL Re-dial last number DP Pulse dialing enabled í DT Tone dialing enabled/Pulse dialing disabled DW Dialing resumed following dial tone detection D, Dialing paused for amount of time specified in S8 register D"WXY" Optional method of denoting telephone numbers. Letters enclosed in quotes are interpreted as numbers according to the system found on a telephone keypad. D! Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. D@ Wait for Quite Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. D; Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. FLOW CONTROL Type: Immediate Format: AT [cmds] &K [cmds] Description: Configures flow control settings Command Function &K0 Flow control disabled &K3 RTS/CTS hardware flow control enabled &K4 XON/XOFF software flow control enabled &K5 Transparent XON/XOFF software flow control enabled &K6 RTS/CTS & XON/XOFF flow control enabled HAYES SMARTMODEM 300 COMPATIBILITY Type: Configuration Format: AT [cmds] Xn [cmds] Description: Configures modem response and blind dialing capabilities Command Function X0 Sets modem to use Hayes Smartmodem 300 responses and blind dialing X1 Sets modem to use Hayes Smartmodem 300 responses, CONNECT responses, and blind dialing X2 Sets modem to use Hayes Smartmodem 300 responses, CONNECT responses, dial tone detection, and blind dialing X3 Sets modem to use Hayes Smartmodem 300 responses, CONNECT responses, busy detection, and blind dialing í X4 Set modem to use all responses, dial tone detection, and busy signal detection X5 Set modem to use all responses, dial tone detection, and busy signal detection X6 Set modem to use all responses, dial tone detection, and busy signal detection X7 Sets modem to use Hayes Smartmodem 300 responses, dial tone detection, busy signal detection, and blind dialing LINE TYPE Type: Configuration Format: AT [cmds] &Ln [cmds] Description: Selects line type Command Line Type &L0 Switched line (PSTN/Dial-up) REPORT INFORMATION Type: Immediate Format: AT [cmds] In [cmds] Description: Displays information requested Command Function I0 Reports modem model and speed I1 Reports ROM checksum I2 Tests and reports internal memory I3 Reports default speed and modem model I4 Reports firmware ID I9 Reports country ID RESTORE PROFILE ON POWER-UP Type: Configuration Format: AT [cmds] &Yn [cmds] Description: Restores a selected profile into the active profile on power-up (hard reset) Command Function &Y0 Restore profile 0 on power-up SPEAKER VOLUME Type: Configuration Format: AT [cmds] Ln [cmds] Description: Controls speaker volume Command Function L0 Low volume setting L1 Low volume setting L2 Medium volume setting L3 Highest volume setting TEST MODES Type: Immediate Format: AT [cmds] &Tn Description: Selects test options Command Function &T0 End current test &T1 Begin local analog loopback test &T3 Begin local digital loopback test &T6 Begin remote digital loopback test Extended AT Commands AUTO-RETRAIN - AUTO-FALLBACK/FALL-FORWARD Type: Configuration Format: AT [cmds] %En [cmds] Description: Controls auto-retrain mode and fallback/fall-forward Command Function %E0 Auto-retrain disabled %E1 Auto-retrain enabled COMPRESSION Type: Configuration Format: AT [cmds] %Cn [cmds] Description: Selects data compression Command Function %C0 Data compression disabled %C1 MNP5 and V.42bis; or data compression and correction enabled CONNECT MODE Type: Configuration Format: AT [cmds] \Nn [cmds] Description: Controls the type of connection the modem will operate in Command Function \N0 Enables Normal mode \N1 Enables Direct mode \N2 Enables MNP mode í \N3 Enables V.42/MNP/Normal modes \N4 Enables V.42 mode \N5 Enables V.42/MNP/Normal modes \N7 Enables V.42/MNP/Normal modes ERROR CORRECTION Type: Immediate Format: AT [cmds] \Vn [cmds] Description: Reports error correction result codes Command Function \V0 Error correction result codes disabled í \V1 Error correction result codes enabled \V2 Error correction result codes enabled FLOW CONTROL TYPE Type: Configuration Format: AT [cmds] \Qn [cmds] Description: Sets type of flow control used by modem Command Function \Q0 Flow control disabled \Q1 Bi-Directional XON/XOFF flow control enabled \Q3 Bi-Directional RTS/CTS flow control enabled RE-DIALING SUPPRESSION Type: Configuration Format: AT [cmds] %Xn [cmds] Description: Configures re-dialing suppression settings Command Function í %X0 Re-dialing suppression disabled %X1 Re-dialing suppression enabled S(status) -Registers DATA CALLING TONE Type: Register Format AT [cmds] S35=n [cmds] Default: 0 Range: 0, 1 Unit: Unidentified Description: Enables the data calling tone DIAL LINE RATE Type: Register Format AT [cmds] S38=n [cmds] Default: 0 Range: 0 - 19 Unit: Unidentified Description: Sets the 56K dialing rate LOCAL PHONE STATUS Type: Register Format AT [cmds] S90=n [cmds] Default: Unidentified Range: 0, 1 Unit: Unidentified Description: 0=on hook, 1=off hook SLEEP MODE TIMER Type: Register Format AT [cmds] S89=n [cmds] Default: 10 Range: 0, 5 - 255 Unit: seconds Description: Sets the sleep mode timer SYNTHETIC RING DIALING Type: Register Format AT [cmds] S32=n [cmds] Default: 10 Range: Unidentified Unit: dB Description: Sets the volume of the synthetic ring SYNTHETIC RING FREQUENCY Type: Register Format AT [cmds] S33=n [cmds] Default: 0 Range: 0 - 5 Unit: Unidentified Description: Sets the value of the synthetic frequency TRANSMIT LEVEL Type: Register Format AT [cmds] S92=n [cmds] Default: 15 Range: 6 - 15 Unit: dB Description: Sets the transmission level volume V.34 MODUALTION Type: Register Format AT [cmds] S28=n [cmds] Default: 1 Range: 0 - 255 Description: Enables V.34 modulation