MAXTECH CORPORATION XPVS T2 (SF-1133HV/T2) Card Type Modem (asynchronous) Chip Set Unidentified I/O Options Microphone, speaker out, line in, line out Maximum Modem Rate 33.6Kbps Maximum Fax Rate 14.4Kbps Data Modulation Protocol Bell 103/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, V.34+, V.FC Fax Modulation Protocol ITU-T V.17, V.27ter, V.29 Error Correction/Compression MNP5, V.42, V.42bis Fax Class Class I Data Bus 8-bit ISA Card Size Half-length, half-height card [Image] CONNECTIONS Function Label Function Label Line out CN1 Microphone CN3 Line in CN2 Speaker out CN4 USER CONFIGURABLE SETTINGS Setting Label Position Speaker type stereo JP5 Closed Speaker type mono JP5 Open SERIAL PORT ADDRESS Setting JP3/A JP3/B JP3/C COM1 (3F8h) Closed Closed Closed COM2 (2F8h) Open Closed Closed COM3 (3E8h) Closed Open Closed COM4 (2E8h) Open Open Closed PnP Open Open Open INTERRUPT SELECTION IRQ JP2/A JP2/B JP2/C JP2/D JP2/E 2/9 Closed Open Open Open Open 3 Open Closed Open Open Open 4 Open Open Closed Open Open 5 Open Open Open Closed Open 7 Open Open Open Open Closed PnP Open Open Open Open Open SUPPORTED COMMAND SET Basic AT Commands AT, ‘+++’, A/ A, B, E, F, H, M, O, P, T, V, X &C, &G, &T, &W, &Z S Registers S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S16, S18, S25 Voice Commands #BDR, #CLS, #MDL, #MFR, #VBQ?, #VBS, #VBT, #VBT, #VCI, #VLS, #VLS, #VRA, #VRA, #VRN, #VRN, #VRX, #VSD, #VSD, #VSK, #VSK, #VSP, #VSP, #VSR, #VSR, #VSS, #VSS, #VTD, #VTD, #VTS, #VTX Proprietary AT Command Set DISPLAY COMMAND SET Type: Configuration Format: AT [cmds] $ [cmds] Description: Displays basic command set DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string Note: Any combination of modifiers can be used to produce the desired dial functions in sequence. Command Function DL Re-dial last number DP Pulse dialing enabled DR Reverse dial mode DS=n Dial stored telephone number n DT Tone dialing enabled/Pulse dialing disabled DW Dialing resumed following dial tone detection D, Dialing paused for amount of time specified in S8 register D! Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. D@ Wait for Quite Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. D/ Delay 125 msec before dialing D$ Display dialing commands D; Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. REPORT INFORMATION Type: Immediate Format: AT [cmds] In [cmds] Description: Displays information requested Command Function I0 Reports modem model and speed I1 Reports ROM checksum I2 Tests and reports ROM checksum I3 Reports product ID I4 Reports current modem settings I5 Reports active and stored profiles I6 Reports link diagnostics I7 Product configuration SPEAKER VOLUME Type: Configuration Format: AT [cmds] Ln [cmds] Description: Controls speaker volume Command Function L0 Low volume setting L1 Low volume setting L2 Medium volume setting L3 Highest volume setting RESULT CODES Type: Configuration Format: AT [cmds] Qn [cmds] Description: Enables modem to send result codes to the DTE Command Function Q0 Modem sends responses Q1 Modem does not send responses Q2 Displays result codes only in Originate Mode LONG SPACE DISCONNECT Type: Configuration Format: AT [cmds] Yn [cmds] Description: Commands the modem to disconnect after a 1.6 second break is detected Command Function Y0 Configuration profile 0 active upon power on or reset Y1 Configuration profile 1 active upon power on or reset Y2 Factory configuration 0 active upon power on or reset Y3 Factory configuration 1 active upon power on or reset Y4 Factory configuration 2 active upon power on or reset Y6 Reports link diagnostics SOFT RESET Type: Immediate Format: AT [cmds] Zn [cmds] Description: Restores modem profiles previously saved in non-volatile RAM using the &W command. Command Function Z0 Reset and retrieve active profiles set by the Y command Z1 Reset and retrieve active profile 0 Z2 Reset and retrieve active profile 1 Z3 Reset and retrieve factory default profile 0 Z4 Reset and retrieve factory default profile 1 Z5 Reset and retrieve factory default profile 2 ARQ RESULT CODES Type: Configuration Format: AT [cmds] &An [cmds] Description: Selects ARQ result code settings Command Function &A0 Disable ARQ result codes &A1 Enable ARQ result codes &A2 Disable ARQ result codes and V.32 modulation &A3 Enable ARQ result codes and error correction and data compression protocols DTE RATE Type: Configuration Format: AT [cmds] &Bn [cmds] Description: Controls DTE rate Command Function &B0 DTE rate adjust to DCE rate after on-line &B1 Constant DTE rate &B2 Constant DTE rate in ARQ mode, variable in non-ARQ mode DATA TERMINAL READY (DTR) Type: Configuration Format: AT [cmds] &Dn [cmds] Description: Selects modem response to DTR Note: The action each variant of &D causes depends on the setting of &Q Command Function &D0 Modem does not respond to DTR &D1 Modem goes to command mode after DTR goes is off &D2 Modem hands up and returns to the command mode after DTR toggle FACTORY DEFAULT PROFILE Type: Configuration Format: AT [cmds] &F [cmds] Description: Sets values in active profile to values found in the default profile Note: Used primarily for international data transmission Command Function &F0 Recall factory default configuration 0 &F1 Recall factory default configuration profile 1 (hardware flow control enabled) &F2 Recall factory default configuration profile 2 (software flow control enabled) TX FLOW Type: Configuration Format: AT [cmds] &Hn [cmds] Description: Controls TX flow settings Note: Used primarily for international data transmission Command Function &H0 Disable TX flow control &H1 Enable hardware TX flow control (CTS) &H2 Enable software TX flow control (XON/XOFF) &H3 Enable hardware (CTS) and software (XON/XOFF) TX flow control RX FLOW Type: Configuration Format: AT [cmds] &In [cmds] Description: Controls RX flow settings Note: Used primarily for international data transmission Command Function &I0 Disable software RX flow control &I1 Enable software RX flow control (XON/XOFF) &I2 Enable software RX flow control (XON/XOFF), but do not pass XON/XOFF to remote modem or local DTE &I3 Enable HP ENQ/ACK software flow control, host mode &I4 Enable HP ENQ/ACK software flow control, terminal mode &I5 Enable software RX flow control (XON/XOFF) for non-ARQ mode COMPRESSION CONTROL Type: Configuration Format: AT [cmds] &Kn [cmds] Description: Enables compression control options Command Function &K0 Disable V.42bis/MNP5 data compression &K1 Auto data compression &K2 Enable V.42bis/MNP5 data compression &K3 Disable MNP5 data compression COMMUNICATIONS MODE Type: Configuration Format: AT [cmds] &Mn [cmds] Description: Selects communications mode Command Mode &M0 Normal mode enabled &M4 ARQ and Normal modes enabled &M5 ARQ mode enabled AUTOMODE CONNECTION SPEED Type: Configuration Format: AT [cmds] &Nn [cmds] Description: Selects connection speed Command Mode &N0 Enable Automode &N1 Set connection speed to 300bps &N2 Set connection speed to 1200bps &N3 Set connection speed to 2400bps &N4 Set connection speed to 4800bps &N5 Set connection speed to 7200bps &N6 Set connection speed to 9600bps &N7 Set connection speed to 12000bps &N8 Set connection speed to 14400bps &N9 Set connection speed to 16800bps &N10 Set connection speed to 19200bps &N11 Set connection speed to 21600bps &N12 Set connection speed to 24400bps &N13 Set connection speed to 26400bps &N14 Set connection speed to 28800bps &N15 Set connection speed to 31200bps &N16 Set connection speed to 33600bps PULSE DIALING RATIO Type: Configuration Format: AT [cmds] &Pn [cmds] Description: Selects pulse dial make/break ratio Command Function &P0 39/61ms at 10pps (North America) &P1 33/67ms at 10pps (Europe) RTS/CTS Type: Configuration Format: AT [cmds] &Rn [cmds] Description: Selects RTS/CTS options Command Function &R0 Reserved &R1 Modem ignores the RTS signal &R2 Enable RX hardware flow control (RTS) DATA SET READY (DSR) Type: Configuration Format: AT [cmds] &Sn [cmds] Description: Selects DSR options Command Function &S0 DSR forced high &S1 DSR off in command mode, on in on-line mode MINIMUM DCE CONNECTION SPEED Type: Immediate Format: AT [cmds] &Un Description: Selects test options Command Function &U0 Do not set minimum DCE connection speed &U1 Set connection speed to 300bps &U2 Set connection speed to 1200bps &U3 Set connection speed to 2400bps &U4 Set connection speed to 4800bps &U5 Set connection speed to 7200bps &U6 Set connection speed to 9600bps &U7 Set connection speed to 12000bps &U8 Set connection speed to 14400bps &U9 Set connection speed to 16800bps &U10 Set connection speed to 19200bps &U11 Set connection speed to 21600bps &U12 Set connection speed to 24400bps &U13 Set connection speed to 26400bps &U14 Set connection speed to 28800bps &U15 Set connection speed to 31200bps &U16 Set connection speed to 33600bps BREAK CONTROL Type: Configuration Format: AT [cmds] &Yn [cmds] Description: Controls break Command Function &Y0 Destructive break. Does not send break &Y1 Destructive break. Break expedited &Y2 Nondestructive break. Break expedited S(status) -REGISTERS BIT-MAPPED REGISTER S13 Type: Register Format AT [cmds] S13=n [cmds] Unit: Bit-mapped Description: DTR reset, ARQ 1.5K buffer DTR/reset, backspace autodial, +++ hangup BIT-MAPPED REGISTER S15 Type: Register Format AT [cmds] S15=n [cmds] Unit: Bit-mapped Description: Disable V.42bis/MNP MNP incompatability INACTIVITY TIMER Type: Register Format AT [cmds] S19=n [cmds] Default: 0 Range: 0-255 Unit: 1 minute Description: Sets the length of time inactivity timer waits before disconnecting BREAK LENGTH Type: Register Format AT [cmds] S21=n [cmds] Default: 10 Range: 0-255 Unit: .01 second Description: ARQ break length FLOW CONTROL CHARACTER - XON Type: Register Format: AT [cmds] S22=n [cmds] Default: 17 Range: 0-127 Unit: ASCII Description: Sets the character used to represent XON FLOW CONTROL CHARACTER - XOFF Type: Register Format: AT [cmds] S23=n [cmds] Default: 19 Range: 0-127 Unit: ASCII Description: Sets the character used to represent XOFF BIT-MAPPED REGISTER S27 Format AT [cmds] S27=n [cmds] Default: Unidentified Unit: Bit-mapped Description: V.21 @ 300bps, non-trellis encoding, disable 2400 Hz answer tone, 9600 result codes, disable V.32bis, enable V.23 BIT-MAPPED REGISTER S28 Format AT [cmds] S28=n [cmds] Default: 8 Range: 0-255 Unit: 0.1 second Description: Controls V.32 handshake length ANSWER MODE TIMER Type: Register Format AT [cmds] S29=n [cmds] Default: 20 Range: 0-255 Unit: .01 second Description: V.21 answer mode timer BIT-MAPPED REGISTER S32 Type: Register Format: AT [cmds] S32=n [cmds] Unit: Bit-mapped Description: Disable V.FC, V.34, V.34bis, Enable V.8 BIT-MAPPED REGISTER S33 Type: Register Format: AT [cmds] S33=n [cmds] Unit: Bit-mapped Description: Disable 2400, 2743, 2800, 3000, 3200, and 3429 symbol rates, call indicate, V.8 BIT-MAPPED REGISTER S34 Type: Register Format: AT [cmds] S34=n [cmds] Unit: Bit-mapped Description: Disable 8S-2D, 16S-4D, 32S-4D maps