ARCHTEK CORPORATION 3334BR Card Type Modem/Fax card Chip Set Unidentified I/O Options Line out, phone in Maximum Modem Rate 33.6Kbps Maximum Fax Rate 14.4Kbps Data Modulation Protocol Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, V.34bis, Rockwell V.FC Fax Modulation Protocol ITU-T V.17, V.21CH2, V.27ter, V.29 Error Correction/Compression MNP10,MNP5, V.42, V.42bis Fax Class Class I & II Data Bus 8-bit ISA Card Size Half-length [Image] CONNECTIONS Function Label Function Label Line out CN2 Phone in CN3 SERIAL PORT ADDRESS Setting IRQ JP1 JP2 JP3 JP4 JP5 JP6 COM1 IRQ4 Closed Closed Open Open Closed Open (3F8h) COM2 IRQ3 Open Closed Open Closed Open Open (2F8h) COM3 IRQ4 Closed Open Open Open Closed Open (3E8h) COM3 IRQ5 Closed Open Open Open Open Closed (3E8h) COM4 IRQ3 Open Open Open Closed Open Open (2E8h) COM4 IRQ2 Open Open Closed Open Open Open (2E8h) SUPPORTED COMMAND SET Basic AT Commands AT, ‘+++’, ‘comma’, A/ A, B, C, E, H, M, O, P, Q, R, S, T, V, W, X, Y, Z &C, &D, &G, &L, &M, &P, &Q, &R, &V, &W, &X, &Y, &Z Extended AT Commands \A, \B, \G, \K %C, %E S Registers S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S18, S25, S26, S30, S32, S33 S36, S38, S91, S92, S95 Special Commands *H, -K, -Q, )M, :E Note: See MHI Help File for full command documentation. PROPRIETARY AT COMMAND SET DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string Note: Any combination of modifiers can be used to produce the desired dial functions in sequence. Command Function DP Pulse dialing enabled DR Answer mode enabled; originate mode disabled following handshake initiation. DS=n Dial stored telephone number n DT Tone dialing enabled/Pulse dialing disabled DW Dialing resumed following dial tone detection D! Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. D@ Wait for Quite Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. D; Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. SPEAKER VOLUME Type: Configuration Format: AT [cmds] Ln [cmds] Description: Controls speaker volume Command Function L0 Low volume setting L1 Low volume setting L2 Medium volume setting L3 Highest volume setting AUTO-MODE DETECTION Type: Configuration Format: AT [cmds] Nn [cmds] Description: Selects various options for the automatic detection and negotiation of protocols during the handshake process if the modem is communicating with a remote modem of dissimilar speed. Command Function N0 In originate mode, handshake only at line speed designated by the S37 register. N1 In originate mode, handshake begins at line speed designated by the S37 register. Modem can shift to a slower speed if necessary. FACTORY DEFAULT PROFILE Type: Configuration Format: AT [cmds] &F [cmds] Description: Sets values in active profile to values found in the default profile Command Function &F0 Sets values to factory configuration 0 &F1 Sets values to factory configuration 1 FLOW CONTROL Type: Configuration Format: AT [cmds] &Kn [cmds] Description: Enables flow control options Command Function &K0 Flow control disabled &K1 Reserved &K2 Reserved &K3 RTS/CTS flow control enabled &K4 XON/XOFF flow control enabled &K5 Transparent XON/XOFF flow control enabled &K6 Hardware and software flow control enabled DATA SET READY (DSR) Type: Configuration Format: AT [cmds] &Sn [cmds] Description: Selects DSR options Command Function &S0 DSR forced high &S1 DSR high only while modem is handshaking S(STATUS) -REGISTERS BIT-MAPPED REGISTER S14 Format: AT [cmds] S14=n [cmds] Range: 0-174 Unit: Bit-mapped Description: Controls echo, loopback tests, analog, digital, remote digital, and self tests. Bit Value Function 0 0 Not used 1 0 Command echo disabled 1 Command echo enabled 3 0 Modem not in remote digital loopback 1 Remote digital loopback in process 3 0 Remote digital loopback not requested 1 Remote digital loopback requested 5 0 Remote digital loopback with self test disabled 1 R Remote digital loopback with self test enabled 6 0 Local analog loopback with self test disabled 1 Local analog loopback with self test enabled BIT-MAPPED REGISTER S19 Format: AT [cmds] S19=n [cmds] Unit: Bit-mapped Description: Defines options for AutoSync operation. Bit Value Function 0 0 Not used 1 0 BSC format enabled 1 HDLC format enabled 2 0 Address detection disabled 1 Address detection disabled 3 0 NRZI coding enabled 1 NZI coding enabled 4 0 Mark idle enabled 1 Flag or sync idle enabled HDLC ADDRESS OR BSC SYNC Format AT [cmds] S20=n [cmds] Range: 0-255 Unit: Bit-mapped Description: Defines the HDLC address or BSC Sync character for AutoSync operation. BIT-MAPPED REGISTER S21 Format: AT [cmds] S21=n [cmds] Unit: Bit-mapped Description: Indicates the status of command options Bit Value Function 0 0 Set by &J but otherwise not used 1 0 Not used 2 0 CTS tracks RTS (&R0) 1 CTS always on (&R1) 3-4 0 DTR (&D0) 1 DTR (&D1) 2 DTR (&D2) 3 DTR (&D3) 5 0 RSDL(&C0) 1 RSDL(&C1) 6 0 DSR(&S0) 1 DSR(&S1) 7 0 Long space disconnect(&Y0) 1 Long space disconnect(&Y1) BIT-MAPPED REGISTER S22 Format AT [cmds] S22=n [cmds] Range: 0-255 Unit: Bit-mapped Description: Controls speaker volume and controls, limits results codes, and pulse dial make/break ratio. Bit Value Function 1, 0 00 Off volume 01 Low level volume 10 Medium level volume 11 High level volume 3, 2 00 Speaker off 01 Speaker off on carrier 10 Speaker on medium 11 Speaker on high DCE LINE SPEED Type: Register Format AT [cmds] S37=n [cmds] Description: Sets the maximum allowable data exchange rate attempted during handshake process. Command Function S37=0 Speed of last connection S37=1 300bps S37=2 300bps S37=3 300bps S37=5 1200bps S37=6 2400bps S37=7 V.23 S37=8 4800bps S37=9 9600bps S37=10 12.0Kbps S37=11 14.4Kbps S37=12 7200bps FLOW CONTROL Type: Register Format AT [cmds] S39? [cmds] Description: Displays the current flow control Value Meaning 0 Flow control disabled 3 RTS/CTS flow control enabled 4 XON/XOFF flow control enabled 5 Transparent XON/XOFF flow control enabled 6 XON/XOFF and RTS/CTS flow control enabled BIT-MAPPED REGISTER S40 Format: AT [cmds] S40=n [cmds] Unit: Bit-mapped Description: General option status Bit Value Function 0-1 0 Disable extended services (-K0) 1 Enable extended services (-K1) 2 Enable extended services (-K2) 1 0 Not used 2 0 CTS tracks RTS (&R0) 1 CTS always on (&R1) 3-4 0 DTR (&D0) 1 DTR (&D1) 2 DTR (&D2) 3 DTR (&D3) 5 0 RSDL(&C0) 1 RSDL(&C1) 6 0 DSR(&S0) 1 DSR(&S1) 7 0 Long space disconnect(&Y0) 1 Long space disconnect(&Y1) BIT-MAPPED REGISTER S41 Format AT [cmds] S41=n [cmds] Range: 0-31 Unit: Bit-mapped Description: Selects compression, auto-retrain, flow control, and MNP mode. Bit Value Function 1 - 0 00 Data compression disabled 01 MNP5 enabled 10 V.42bis enabled 11 MNP5 and V.42bis enabled 2,6 0 Auto-retrain disabled 1 Auto-retrain enabled 10 Fallback/fall forward enabled 4 0 Stream mode for MNP 1 Block mode for MNP 7 0 Fallback to V.22bis/V22 disabled 1 Fallback to V.22bis/V22 enabled ERROR CORRECTION/COMPRESSION Type: Register Format: AT [cmds] S46=n [cmds] Description: Selects active error correction and compression protocols Command Function S46=136 LAP-M only, no compression S46=138 LAP-M with V.42bis data compression FEATURE NEGOTIATION OPTIONS Type: Register Format: AT [cmds] S48=n [cmds] Description: Selects active error correction and compression protocols Command Function S48=0 Detection negotiation disabled, XID negotiation disabled S48=7 Detection negotiation and XID negotiation enabled S48=128 Fall-back to options set in S36 CONNECTION FAILURE CODES Type: Register Format AT [cmds] S86? [cmds] Description: Reports codes which correspond to the possible causes of a connection failure Value Meaning 0 Normal hang up 4 Carrier signal lost 5 No error-control detected for remote modem during feature negotiation 9 No common protocol found 12 No failure - remote modem disconnected normally 13 Remote modem failed to respond after 10 re-transmissions same message 14 Violation of negotiated protocol caused failure TRANSMISSION LEVEL - CELLULAR Type: Register Format: AT [cmds] S201=n [cmds] Description: Sets the signal level for transmission Bit Function 0-4 Initial cellular power setting @Mn 5 Compromise equalizer enable command