RAD DATA COMMUNICATIONS FOM-400 Card Type T1/E1 signal converter Chipset Unidentified Topology Peer-Peer Wire Type Fiber optic cable T1/E1 Transfer Rate 1.544Mbps/2.048Mbps T1/E1 Protocol AMI, HDB3 Frame Type Unidentified Data Bus Proprietary [Image] CONNECTIONS Function Label Function Label T1/E1 line in CN1 Primary fiber optic CN6 transmit connector T1/E1 line out CN2 Control port (see CN7 pinout below) Secondary fiber optic CN3 DC power in CN8 receive connector Secondary fiber optic CN4 AC power in CN9 transmit connector Primary fiber optic CN5 Power switch SW1 receive connector CN7 PINOUT Function Pin Function Pin Chassis ground 1 Primary/secondary fiber 14 optic channel indicator signal Not used 2 Not used 15 Not used 3 T1/E1 connection broken 16 relay T1/E1 connection 4 Not used 17 broken signal Not used 5 Not used 18 Not used 6 T1/E1 connection broken 19 relay Signal ground 7 Alarm condition signal 20 Not used 8 Not used 21 Not used 9 Primary/secondary fiber 22 optic channel selection Not used 10 Secondary fiber optic 23 connection broken signal Not used 11 Not used 24 Not used 12 Primary fiber optic 25 connection broken signal Not used 13 Not used USER CONFIGURABLE SETTINGS Setting Label Position Signal ground connected to chassis ground JP1 Pins 1 & 2 closed Signal ground not connected to chassis JP1 Pins 2 & 3 ground closed Primary fiber optic channel set for SW2 On short-range operation Primary fiber optic channel set for SW2 Off long-range operation Secondary fiber optic channel set for SW3 On short-range operation Secondary fiber optic channel set for SW3 Off long-range operation T1/E1 interface set for 100ohm or 120ohm SW4 On balanced cable T1/E1 interface set for 75ohm unbalanced SW4 Off cable FIBER OPTIC CHANNEL SELECTION Setting SW5 » Channel selected by control port Position 2 Primary channel active Position 1 Secondary channel active Position 3 DIAGNOSTIC LED(S) LED Color Status Condition LED1 Green On AC power source is connected at CN9 LED1 Green Off AC power source is not connected at CN9 LED2 Green On Backup DC power is connected to CN8 LED2 Green Off Backup DC power is not connected to CN8 LED3 Red On Internal power supply failed LED3 Red Off Internal power supplies are good LED4 Green On DSU is receiving data LED4 Green Off DSU is not receiving data LED5 Green On DSU is transmitting data LED5 Green Off DSU is not transmitting data LED6 Red On Fiber optic synchronization lost LED6 Red Off Fiber optic synchronization good LED7 Yellow On Primary fiber optic channel in use LED7 Yellow Off Primary fiber optic channel not in use LED8 Red On Primary fiber optic channel receive level less than -39dBm LED8 Red Off Primary fiber optic channel receive level more than -39dBm LED9 Yellow On Secondary fiber optic channel in use LED9 Yellow Off Secondary fiber optic channel not in use LED10 Red On Secondary fiber optic channel receive level less than -39dBm LED10 Red Off Secondary fiber optic channel receive level more than -39dBm