DIALOGIC CORPORATION D/21D, D/41D (REV. 2) Card Type Telephony I/O Options AEB bus Data Bus 8-bit ISA Line Type Loop-start [Image] CONNECTIONS Function Label Function Label Microprocessor interface P2 Analog expansion bus P3 USER CONFIGURABLE SETTINGS Setting Label Position » IRQ termination enabled JP7 Open IRQ termination disabled JP7 Closed » Board will use internal loop-start JP8 Installed interface for input Board will use T1 interface via AEB JP8 Not installed bus for input » Disabled board will not answer SW1/4 Off incoming calls Disabled board will send busy signal SW1/4 On to incoming calls Note:If multiple D/4x cards are installed in a system, JP7 should be closed for only one of them. BASE I/O ADDRESS Setting JP5 JP6 SW1/1 SW1/2 SW1/3 A0000h Closed Open Off Off Off A2000h Closed Open Off Off On A4000h Closed Open Off On Off A6000h Closed Open Off On On A8000h Closed Open On Off Off AA000h Closed Open On Off On AC000h Closed Open On On Off AE000h Closed Open On On On B8000h Closed Closed Off Off Off BA000h Closed Closed Off Off On BC000h Closed Closed Off On Off BE000h Closed Closed Off On On BASE I/O ADDRESS (CON’T) Setting JP5 JP6 SW1/1 SW1/2 SW1/3 C0000h Closed Closed On Off Off C0000h Open Closed Off Off Off C2000h Closed Closed On Off On C2000h Open Closed Off Off On C4000h Closed Closed On On Off C4000h Open Closed Off On Off C6000h Closed Closed On On On C6000h Open Closed Off On On C8000h Open Closed On Off Off CA000h Open Closed On Off On CC000h Open Closed On On Off CE000h Open Closed On On On » D0000h Open Open Off Off Off D2000h Open Open Off Off On D4000h Open Open Off On Off D6000h Open Open Off On On D8000h Open Open On Off Off DA000h Open Open On Off On DC000h Open Open On On Off DE000h Open Open On On On INTERRUPT Setting JP1/A JP1/B JP1/C JP1/D JP1/E JP1/F » IRQ2 Closed Open Open Open Open Open IRQ3 Open Closed Open Open Open Open IRQ4 Open Open Closed Open Open Open IRQ5 Open Open Open Closed Open Open IRQ6 Open Open Open Open Closed Open IRQ7 Open Open Open Open Open Closed Note: All D/4xx boards in the system should be set to the same interrupt.