ADC KENTROX T-SERV II Card Type T1 CSU Chip Set Unidentified I/O options Diagnostic ports Maximum Transfer Rate 1.544Mbps Data Bus External Data Modulation Protocol B8ZS [Image] CONNECTIONS Function Label Function Label T1 line out CN1 Test signal to network CN8 Network line out CN2 Test signal from CN9 equipment RS-232/422 CN3 Monitor signal from CN10 equipment DC power CN4 Ground SC1 Test signal to equipment CN5 Test switch SW1 Test signal from network CN6 Alarm cut-off SW2 Monitor signal from CN7 network USER CONFIGURABLE SETTINGS Setting Label Position » Test signals not sent through pulse SW5/1 On density circuits Test signals sent through pulse SW5/1 Off density circuits » Force sending of digital ON after 15 SW5/2 Off OFF signals Force sending of digital ON after 47 SW5/2 On OFF signals » QRSS will not cause low pulse density SW5/3 On error QRSS will cause low pulse density SW5/3 Off error three times every two seconds » Pulse density monitor enabled SW5/4 Off Pulse density monitor disabled SW5/4 On » Use unframed keep-alive signal SW5/5 On Use framed keep-alive signal SW5/5 Off » Factory configured - do not alter SW5/6 N/A » Factory configured - do not alter SW5/7 N/A » Factory configured - do not alter SW5/8 N/A SIGNAL ATTENUATION Setting SW3 SW4 0dBm On On -7.5dBm On Off -15dBm Off On -22.5dBm Off Off POWER SOURCE Setting JP1 Local power Up Line power Down DIAGNOSTIC LED(S) LED Color Status Condition LOC LP Yellow On CSU is in local loopback test mode LOC LP Yellow Off CSU is not in local loopback test mode CODE Yellow On CSU received a reset signal CODE Yellow Off CSU did not receive a reset signal NET LP Yellow On Remote CSU is in loopback test mode NET LP Yellow Off Remote CSU is not in loopback test mode SEND/FEL Yellow On CSU is transmitting a reset signal SEND/FEL Yellow Off CSU is not transmitting a reset signal SEND/FEL Yellow Blinking CSU is in remote loopback test mode PWR Green On Power is on PWR Green Off Power is off ACO Green On An alarm has occurred but has been silenced ACO Green Off No alarm has occurred or the alarm is active KA Red On CSU is sending a keep-alive signal KA Red Off CSU is not sending a keep-alive signal LOS Red On Signal not detected LOS Red Off Signal detected AIS Red On CSU is receiving a keep-alive signal AIS Red Off CSU is not receiving a keep-alive signal BPV Red On CSU has detected bipolar variations BPV Red Off CSU has not detected bipolar variations BPV Red Blinking CSU has detected bipolar variations