OLICOM, INC. OC-7111 Card Type Fax, Modem (asynchronous) Chip Set Unidentified Maximum Data Rate 28.8Kbps Maximum Fax Rate 14.4Kbps Data Bus PCMCIA Type II Fax Class Class I & II Data Modulation Protocol Bell 103/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34 Rockwell V.FC Fax Modulation Protocol ITU-T V.17, V.21CH2, V.27ter, V.29 Error Correction/Compression MNP5, MNP10, V.42, V.42bis V1942 MISCELLANEOUS TECHNICAL NOTES Note: Due to country specific parameters, S-register settings are unidentified. Proprietary AT Command Set AUTOSYNC™ Format AT [cmds] S19=n [cmds] Default: Unidentified Range: 0-30 Unit: Bit-mapped Description: Sets options for Hayes AutoSync™ functions. Bit Value Function 0 0 Not used. 1 0 BSC enabled. 1 HDLC enabled. 2 0 HDLC address detection disabled. 1 HDLC address detection enabled. 3 0 NRZI bit encoding enabled. 1 NRZ2 bit encoding enabled. 4 0 Mark idle enabled. 1 Flag or sync idle enabled. AUTOSYNC HDLC ADDRESS Type: Register Format: AT [cmds] S20=n [cmds] Default: Unidentified Range: 0-255 Unit: Unidentified Description: Sets the HDLC address/BSC character AUTO-RETRAIN - AUTO-FALLBACK/FALL-FORWARD Type: Configuration Format: AT [cmds] %En [cmds] Description: Controls auto-retrain mode and fallback/fall-forward Command Function %E0 Auto-retrain disabled %E1 Auto-retrain enabled %E2 Auto-fallback/fall-forward enabled %E3 Auto-retrain enabled with fast hang-up BIT MAPPED REGISTERS Register Default S14 Unidentified S21 Unidentified S22 Unidentified S23 Unidentified S27 Unidentified S28 Unidentified S31 Unidentified S40 Unidentified S41 Unidentified S201 Unidentified BREAK SEND Type: Configuration Format: AT [cmds] \Bn [cmds] Default: 3 Range: 1-9 Unit: .1 second Description: Sends break to modem BREAK TYPE Type: Configuration Format: AT [cmds] \Kn [cmds] Description: Configures action of break signal Command Break from DTE Modem receives Break received \B from remote modem \K0 Online command Break sent to Buffers cleared, mode enabled, remote modem and break sent to DTE send no break buffered cleared to remote modem \K1 Break sent to Break sent to Buffers cleared, remote modem remote modem and break sent to DTE and buffered buffered cleared cleared \K2 Online command Send break to Break sent mode enabled, remote modem immediately to send no break immediately DTE to remote modem \K3 Send break to Send break to Break sent remote modem remote modem immediately to immediately immediately DTE \K4 Online command Send break with Break sent with mode enabled, transmitted data received data to send no break the DTE to remote modem \K5 Send break with Send break with Break sent with transmitted transmitted data received data to data the DTE COUNTRY CODE Type: Configuration Format: AT [cmds] *NCnn [cmds] Description: Select a country code from NVRAM (nn=00-08) DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string Note: Any combination of modifiers can be used to produce the desired dial functions in sequence. Command Function DJ Link will be negotiated at 1200bps for current call only DK Power level adjustment enabled for current call only DL Re-dial last number DP Pulse dialing enabled DT Tone dialing enabled/Pulse dialing disabled DR Accepted but not used. DS=n Dial stored telephone number n D! Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. DW Dialing resumed following dial tone detection D@ Wait for Quiet Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. D, Dialing paused for amount of time specified in S8 register D; Modem returned to command state after dialing. The semicolon can only be placed at the end of the dial command. D^ Calling tone enabled/disabled for current dialing attempt DIALING CODE Type: Configuration Format: AT [cmds] *Zn [cmds] Description: Select the dial code for pulse dialing Command Function *Z0 Use dial code 0 *Z1 Use dial code 1 DELAYED NUMBERS Type: Immediate Format: AT [cmds] *B [cmds] Description: Displays delayed numbers list DELAYED NUMBERS Type: Immediate Format: AT [cmds] *D [cmds] Description: Displays delayed numbers list COMPRESSION Type: Configuration Format: AT [cmds] %Cn [cmds] Description: Selects data compression Command Function %C0 Data compression disabled %C1 MNP5 enabled %C2 V.42bis enabled %C3 MNP5 and V.42bis enabled CONNECT MODE Type: Configuration Format: AT [cmds] \Nn [cmds] Description: Controls the type of connection the modem will operate in Command Function \N0 Normal mode enabled \N1 Direct mode enabled \N2 MNP reliable mode enabled \N3 Auto-reliable mode enabled \N4 V.42 reliable mode enabled \N5 MNP auto-reliable mode enabled FLASH DIAL MODIFIER TIME Type: Register Format AT [cmds] S29=n [cmds] Default: 0 Range: 0-255 Unit: Unidentified Description: Time the modem will go on-hook upon receiving the ! dial modifier in dial string. FLOW CONTROL Type: Configuration Format: AT [cmds] \Gn [cmds] Description: Selects modem port flow control Command Function \G0 Flow control disabled \G1 Flow control enabled FLOW CONTROL CHARACTER - XOFF Type: Register Format: AT [cmds] S33=n [cmds] Default: 19 Range: 0-255 Unit: ASCII Description: Sets the character used to represent XOFF FLOW CONTROL CHARACTER - XON Type: Register Format: AT [cmds] S32=n [cmds] Default: 17 Range: 0-255 Unit: ASCII Description: Sets the character used to represent XON LINE SIGNAL LEVEL Type: Immediate Format: AT [cmds] %L [cmds] Description: Returns a value which indicates the received line signal level LINE SIGNAL QUALITY Type: Immediate Format: AT [cmds] %Q [cmds] Description: Returns a value which indicates line signal quality LOCK SERIAL PORT Type: Configuration Format: AT [cmds] \Jn [cmds] Description: Sets operation of serial port speed Command Function \J0 Serial speed locked \J1 Serial speed follows connect speed MAXIMUM BLOCK SIZE FOR TRANSMISSION Type: Configuration Format: AT [cmds] \An [cmds] Description: Sets the maximum transmittable block size Command Function \A0 MNP block size is 64 characters \A1 MNP block size is 128 characters \A2 MNP block size is 192 characters \A3 MNP block size is 256 characters MODULATION SELECTION DISPLAY Type: Immediate Format: AT [cmds] +MS? [cmds] Description: Displays modulation, automode, minimum rate and maximum rate settings Command Function +MS=? Displays supported mode selection MODULATION SELECTION Type: Configuration Format: AT [cmds] +MS=x,y,z,a [cmds] Description: Sets options for active protocol; the transfer rates specified by z and a must be valid for the protocol selected. Command Function x=0 V.21 x=1 V.22 x=2 V.22bis x=3 V.23 x=9 V.32 x=10 V.32bis x=11 V.34 x=64 Bell 103 x=69 Bell 212A x=74 V.FC y=0 Automode disabled y=1 Auto-detect highest speed enabled z, a=300 Set minimum or maximum transfer rate at 300bps, respectively. z, a=1200 Set minimum or maximum transfer rate at 1200bps, respectively. z, a=2400 Set minimum or maximum transfer rate at 2400bps, respectively. z, a=4800 Set minimum or maximum transfer rate at 4800bps, respectively. z, a=7200 Set minimum or maximum transfer rate at 7200bps, respectively. z, a=9600 Set minimum or maximum transfer rate at 9600bps, respectively. z, a=12000 Set minimum or maximum transfer rate at 12000bps, respectively. z, a=14400 Set minimum or maximum transfer rate at 14400bps, respectively. z, a=16800 Set minimum or maximum transfer rate at 16800bps, respectively. z, a=19200 Set minimum or maximum transfer rate at 19200bps, respectively. z, a=21600 Set minimum or maximum transfer rate at 21600bps, respectively. z, a=24000 Set minimum or maximum transfer rate at 24000bps, respectively. z, a=26400 Set minimum or maximum transfer rate at 26400bps, respectively. z, a=28800 Set minimum or maximum transfer rate at 28800bps, respectively. MNP - EXTENDED SERVICES Type: Configuration Format: AT [cmds] -Kn [cmds] Description: Selects MNP extended services Command Function -K0 MNP extended services disabled -K1 MNP extended services enabled MNP - STREAM/BLOCK MODE Type: Configuration Format: AT [cmds] \Ln [cmds] Description: Selects the transfer mode for MNP link Command Function \L0 Stream mode for MNP enabled \L1 Block mode for MNP enabled MNP10 - FALLBACK Type: Configuration Format: AT [cmds] -Qn [cmds] Description: Allows MNP10 to fall back to speeds slower than 4800bps Command Function -Q0 MNP10 at 2400 and 1200bps enabled -Q1 MNP10 at 2400 and 1200bps disabled MNP10 - LINK NEGOTIATION Type: Configuration Format: AT [cmds] *Hn [cmds] Description: Sets the speed at which MNP10 link negotiation will occur Command Function *H0 Link will be negotiated at highest possible speed *H1 Link will be negotiated at 1200bps *H2 Link will be negotiated at 4800bps MNP10 - POWER LEVEL ADJUST Type: Configuration Format: AT [cmds] )Mn [cmds] Description: Controls automatic transmit power level adjustment during MNP 10 link negotiation Command Function )M0 Power level adjustment disabled )M1 Power level adjustment enabled REPORT INFORMATION Type: Immediate Format: AT [cmds] In [cmds] Description: Displays information requested Command Function I0 Reports product code I1 Reports ROM checksum I2 Calculates and reports ROM checksum I3 Reports firmware level I5 Reports country code SLEEP TIMER Type: Register Format AT [cmds] S24=n [cmds] Default: 0 Range: Unidentified Unit: Unidentified Description: Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode. STORED NUMBERS Type: Immediate Format: AT [cmds] \Fn [cmds] Description: Displays phone number directory TEST MODES Type: Register Format: AT [cmds] S16=n [cmds] Default: Unidentified Range: 0-125 Unit: Bit-mapped Description: Controls loopback tests, analog, digital, remote digital, and self tests. Bit Value Function 0 0 Local analog loopback not in progress 1 Local analog loopback in progress 1 0 Not used 2 0 Local digital loopback not in progress 1 Local digital loopback in progress 3 0 Modem not in remote digital loopback 1 Remote digital loopback in progress 4 0 Remote digital loopback not requested 1 Remote digital loopback requested 5 0 Remote digital loopback w/ self-test not in progress 1 Remote digital loopback w/ self-test in progress 6 0 Local analog loopback w/ self-test not in progress 1 Local analog loopback w/ self-test in progress TRANSMISSION LEVEL - CELLULAR Type: Configuration Format: AT [cmds] @Mn [cmds] Default: Unidentified Range: 0-31 Unit: -1dBm Description: Sets the signal level for transmission while in cellular mode TRANSMISSION LEVEL - FAX Type: Register Format: AT [cmds] S92=n [cmds] Default: Unidentified Range: 0-15 Unit: -1 dBm Description: Sets the signal level for transmission while in fax mode TRANSMISSION LEVEL - PSTN Type Register Format AT [cmds] S91=n [cmds] Default Unidentified Range 0-15 Unit -1 dBm Description Sets the signal level for transmission over switched phone lines V.32 - COMPROMISE EQUALIZER Type: Configuration Format: AT [cmds] :En [cmds] Description: Controls V.32 compromise equalizer Command Function :E0 Equalizer disabled :E1 Equalizer enabled