RAD DATA COMMUNICATIONS ASM-20 G.703 Modem Type Data (Synchronous) Maximum Data Rate 64Kbps Data Bus External Data Modulation Protocol Proprietary [Image] CONNECTIONS Purpose Location Purpose Location G-703 CN1 Diagnostic test switch DIG AC power CN2 Analog loopback switch ANA Ground GND Remote loopback switch REM Receive RCV Test pattern PATT Transmit XMT CD SIGNAL Setting JP1 CD normal Pins 2 & 3 closed » CD forced high Pins 1 & 2 closed CHASSIS TO SIGNAL GROUND Setting JP6 » Connected Pins 2 & 3 closed Disconnected Pins 1 & 2 closed ENABLE PUSHBUTTONS Setting JP5 » DIG, ANA, REM, PATT enabled Pins 1 & 2 closed Disabled Pins 2 & 3 closed JITTER FILTER Setting JP8 Enabled Pins 1 & 2 closed » Disabled Pins 2 & 3 closed RECEIVE IMPEDANCE Setting JP4 » 135omhs Pins 1 & 2 closed Low Pins 2 & 3 closed TRANSMIT IMPEDANCE Setting JP3 » 135omhs Pins 1 & 2 closed Low Pins 2 & 3 closed TRANSMIT LEVEL Setting JP2 » 0dBm Pins 2 & 3 closed -6dBm Pins 1 & 2 closed V.54 DELAY Setting JP7 » On Pins 2 & 3 closed Off Pins 1 & 2 closed DIAGNOSTIC LED(S) LED Color Status Condition PWR Green On Power is on PWR Green Off Power is off RTS Yellow On Request to Send enabled RTS Yellow Off Request to Send disabled TD Yellow On Modem is transmitting steady SPACE TD Yellow Off Modem is not transmitting data TD Yellow Blinking Modem is transmitting data RD Yellow On Modem is receiving steady SPACE RD Yellow Off Modem is not receiving data RD Yellow Blinking Modem is receiving data DCD Yellow On Carrier signal detected DCD Yellow Off Carrier signal not detected TEST Red On Modem in test mode TEST Red Off Modem not in test mode ERR Yellow On Errors in test pattern ERR Yellow Off Good test pattern