RAD DATA COMMUNICATIONS ASM-45 Modem Type Data (Synchronous) Maximum Data Rate 768Kbps Data Bus External Data Modulation Protocol Proprietary [Image] CONNECTIONS Purpose Location Purpose Location V.35/X.21/RS-530 CN1 Fuse FUSE AC power CN2 Digital loopback DIG switch Ground GND Analog loopback ANA switch Receive RCV Remote loopback REM switch Transmit XMT Test pattern PATT ANALOG LOOPBACK Setting JP5 Enabled Pins 2 & 3 closed » Disabled Pins 1 & 2 closed BAUD RATE Setting JP1/A JP1/B JP1/C JP1/D JP1/E 768Kbps Closed Open Open Open Open 512Kbps Open Closed Open Open Open 384Kbps Open Open Closed Open Open » 256Kbps Open Open Open Closed Open 128Kbps Open Open Open Open Closed CD SIGNAL Setting JP3 CD normal Pins 2 & 3 closed » CD forced high Pins 1 & 2 closed CHASSIS TO SIGNAL GROUND Setting JP9 » Connected Pins 1 & 2 closed Disconnected Pins 2 & 3 closed CLOCK SOURCE Setting JP2/A JP2/B JP2/C External Closed Open Open » Internal Open Closed Open Receive Open Open Closed REMOTE LOOPBACK Setting JP6 Enabled Pins 2 & 3 closed » Disabled Pins 1 & 2 closed TRANSMIT LEVEL Setting JP4 » 0dBm Pins 2 & 3 closed -6dBm Pins 1 & 2 closed V.54 DELAY Setting JP7 » Off Pins 1 & 2 closed On Pins 2 & 3 closed X.21 CLOCK SOURCE Setting JP8 External Pins 1 & 2 closed » Internal Pins 2 & 3 closed DIAGNOSTIC LED(S) LED Color Status Condition PWR Green On Power is on PWR Green Off Power is off RTS Yellow On Request to Send enabled RTS Yellow Off Request to Send disabled TD Yellow On Modem is transmitting steady SPACE TD Yellow Off Modem is not transmitting data TD Yellow Blinking Modem is transmitting data RD Yellow On Modem is receiving steady SPACE RD Yellow Off Modem is not receiving data RD Yellow Blinking Modem is receiving data DCD Yellow On Carrier signal detected DCD Yellow Off Carrier signal not detected TEST Red On Modem in test mode TEST Red Off Modem not in test mode ERR Yellow On Errors in test pattern ERR Yellow Off Good test pattern