RAD DATA COMMUNICATIONS SRM-6SC Modem Type Data (Synchronous) Maximum Data Rate 19.2 Data Bus External Data Modulation Protocol Proprietary [Image] CONNECTIONS Purpose Location Purpose Location RS-232 CN1 Ground GND RJ-12/RJ-45 CN2 Transmit XMT Receive RCV BAUD RATE Setting SW1 19.2Kbps 0 14.4Kbps 1 » 9.6Kbps 2 7.2Kbps 3 4.8Kbps 4 3.6Kbps 5 2.4Kbps 6 1.8Kbps 7 1.2Kbps 8 900bps 9 CD SIGNAL Setting JP2 » Forced high Pins 1 & 2 closed Normal Pins 2 & 3 closed CLOCK SOURCE Setting JP2/A JP2/B JP2/C External Open Closed Open » Internal Open Open Closed Receive Closed Open Open RTS/CTS DELAY Setting JP3 » 7ms Pins 2 & 3 closed 53ms Pins 1 & 2 closed