U.S. ROBOTICS, INC. SPORTSTER 1200PC Modem Type Data (synchronous/asynchronous) Maximum Data Rate 1200bps Data Bus 8-bit ISA Data Modulation Bell 103A/212A Protocol [Image] CONNECTIONS Purpose Location Purpose Location Line out CN1 Volume SW2 Line in CN2 DTR SIGNAL Setting SW1/1 » DTR forced high On DTR normal Off RESULT CODES Setting SW1/2 » Verbose result codes enabled Off Numeric result codes enabled On RESULT CODES DISPLAY Setting SW1/3 » Display enabled On Display disabled Off ECHO COMMANDS DISPLAY Setting SW1/4 » Local echo enabled Off Local echo disabled On AUTO ANSWER Setting SW1/5 » Modem does not answer on first On ring Modem answers on first ring Off CARRIER DETECT Setting SW1/6 » CD normal Off CD forced high On MULTLINE INSTALLATION Setting SW1/7 » Single phone connected Off Multiple phones connected On AT COMMAND SET Setting SW1/8 » AT command set recognized On AT command set disabled Off COM PORT CONFIGURATION Port J1 J2 COM1: (3F8h) Pins 1 & 2 closed Pins 1 & 2 closed COM2: (3E8h) Pins 2 & 3 closed Pins 1 & 2 closed COM3: (2F8h) Pins 1 & 2 closed Pins 2 & 3 closed COM4: (2E8h) Pins 2 & 3 closed Pins 2 & 3 closed INTERRUPT SELECTION IRQ J3 3 Pins 3 & 5 closed 4 Pins 1 & 3 closed 5 Pins 2 & 4 closed 7 Pins 4 & 6 closed Disabled Open Proprietary AT Command Set ANALOG LOOPBACK SELF TEST Type: Register Format: AT [cmds] S16=n [cmds] Example: ATS16=139 Description: Selects the tone dialing test. Command Function 0 Data mode. 1 Analog loopback. 2 Dial testing. 4 Test pattern. 5 Analog loopback and test pattern.