QUATECH, INC. DS-225/DS-325 Card Type Serial interface Chipset Controller Unidentified I/O Options Serial ports (2) Maximum Dram N/A [Image] CONNECTIONS Purpose Location Purpose Location Serial port 1 J1 Serial port 2 J2 INTERRUPT SELECTION IRQ JP3 2 Pins 1 & 2 closed 3 Pins 3 & 4 closed 4 Pins 5 & 6 closed 5 Pins 7 & 8 closed 6 Pins 9 & 10 closed 7 Pins 11 & 12 closed SERIAL INTERRUPT SHARING SELECTION Setting JP2 Non-sharable Pins 1 & 2 closed Sharable Pins 2 & 3 closed RS-422/485 DRIVER POWER-UP STATE SELECTION State JP5 Enabled Pins 2 & 3 connected Disabled Pins 1 & 2 connected ADDRESS SELECTION Address SW1/1 SW1/2 SW1/3 SW1/4 SW1/5 SW1/6 SW1/7 SW1/8 000h On On On On On On On On 008h On On On On On On On Off 010h On On On On On On Off On 018h On On On On On On Off Off 2E8h On Off On Off Off Off On Off (COM4:) 2F8h On Off On Off Off Off Off Off (COM2:) 3E8h On Off Off Off Off Off On Off (COM3:) 3F8h On Off Off Off Off Off Off Off (COM1:) 7E0h Off Off Off Off Off Off On On 7E8h Off Off Off Off Off Off On Off 7F0h Off Off Off Off Off Off Off On 7F8h Off Off Off Off Off Off Off Off Note: A total of 255 memory base address settings are available. The switches are a binary representation of the decimal addresses. Switch 8 is the Least Significant Bit and switch 1 is the Most Significant Bit. The switches have the following decimal values: switch 8=1, 7=2, 6=4, 5=8, 4=16, 3=32, 2=64, 1=128. Turn off the switches and add the off switches to obtain the correct memory base address. (On=0, Off=1) DTE/DCE SELECTION JP6 DTE DCE [Image] [Image] INPUT CLOCK DIVISOR SELECT JP1 10 (Default) 5 2 1 [Image] [Image] [Image] [Image] PROTOCOL SELECTION Protocol SW2/1 SW2/2 SW2/3 SW2/4 SW2/5 SW2/6 SW2/7 SW2/8 Software Off Off Off Off Off Off Off Off select RS-232 On On On Off Off On Off Off RS-422/485 On On Off On Off Off On Off Current On On Off Off On Off Off On loop CURRENT LOOP TRANSMIT MODE SELECTION Mode SW3/1 SW3/2 SW3/3 SW3/4 SW3/5 SW3/6 SW3/7 SW3/8 Passive On On Off Off Off Off Off Off 20mA Off Off On On On Off Off Off active 30mA Off Off On On On On Off Off active 60mA On On Off Off Off Off Off On active CURRENT LOOP RECEIVE MODE SELECTION Mode SW4/1 SW4/2 SW4/3 SW4/4 SW4/5 SW4/6 SW4/7 SW4/8 JP4 Passive On On Off Off Off Off Off Off Open 20mA Off Off On On On Off Off Off 1 & 2 active closed 30mA Off Off On On On On Off Off 3 & 4 active closed 60mA On On Off Off Off Off Off On 5 & 6 active closed