EVEREX SYSTEMS, INC. RAM 3000 DELUXE Card Type Memory Card Chipset Controller Unidentified I/O Options N/A Maximum Dram 3072KB [Image] DRAM CONFIGURATION Size Bank 0 Bank 1 Bank 2 Bank 3 Bank 4 Bank 5 512KB (18) NONE NONE NONE NONE NONE 256K x 1 1024KB (18) (18) NONE NONE NONE NONE 256K x 256K x 1 1 1536KB (18) (18) (18) NONE NONE NONE 256K x 256K x 256K x 1 1 1 2048KB (18) (18) (18) (18) NONE NONE 256K x 256K x 256K x 256K x 1 1 1 1 2560KB (18) (18) (18) (18) (18) NONE 256K x 256K x 256K x 256K x 256K x 1 1 1 1 1 3072KB (18) (18) (18) (18) (18) (18) 256K x 256K x 256K x 256K x 256K x 256K x 1 1 1 1 1 1 MEMORY SPEED SELECT Setting JP1 » 120 nano sec Open 150 nano sec Closed PARITY CHECK SELECT Setting JP2 Enabled Closed Disabled Open STARTING ADDRESS/SIZE SELECT Address SW1/1 SW1/2 SW1/3 SW1/4 SW1/6 SW1/7 SW1/8 SW1/9 208h On On On On On On On On 218h On On On Off On On On Off » 258h On Off On Off On Off On Off » 268h On Off Off On On Off Off On 2A8h Off On Off On Off On Off On 2B8h Off On Off Off Off On Off Off 2E8h Off Off Off On Off Off Off On Note: 258h is the default setting for EMS I/O port 1 268h is the default setting for EMS I/O port 2 MISCELLANEOUS TECHNICAL NOTE If you are installing are installing two RAM 3000 Deluxe cards then you can not select 258h or 268h as EMS port addresses on the second card. EMS I/O PORT 1 SELECT Setting SW1/5 Enabled Off Disabled On Note: If EMS port 1 is enabled then the EMS memory is 128KB-2048KB EMS I/O PORT 2 SELECT Setting SW1/10 Enabled Off Disabled On Note: If EMS port 1 & 2 are enabled then the EMS memory is 2049KB-3072KB INSTALLED MEMORY BANKS SELECT Banks SW2/1 SW2/2 SW2/3 0 Off Off Off 1 Off Off On 2 Off On Off 3 Off On On 4 On Off Off 5 On Off On MEMORY BANK SELECT Size SW2/4 SW2/5 SW2/6 SW2/7 SW2/8 0KB Off Off Off Off Off 512KB Off Off On Off Off 1024KB Off On Off Off Off 1536KB Off On On Off Off 2048KB On Off Off Off Off 2560KB On Off On Off Off 3072KB On On Off Off Off STARTING ADDRESS/SIZE SELECT Address Size SW3/2 SW3/3 SW3/4 SW3/5 SW3/6 SW3/7 SW3/8 00000h 0KB Off Off Off Off Off Off Off 20000h 128KB Off Off Off Off Off Off On 40000h 256KB Off Off Off Off Off On Off 60000h 384KB Off Off Off Off Off On On 80000h 512KB Off Off Off Off On Off Off A0000h 640KB Off Off Off Off On Off On 10000h 1024KB Off Off Off On Off Off Off 120000h 1152KB Off Off Off On Off Off On 140000h 1280KB Off Off Off On Off On Off 160000h 1408KB Off Off Off On Off On On 180000h 1536KB Off Off Off On On Off Off 1A0000h 1664KB Off Off Off On On Off On 1C0000h 1792KB Off Off Off On On On Off 1E0000h 1920KB Off Off Off On On On On 200000h 2048KB Off Off On Off Off Off Off 220000h 2176KB Off Off On Off Off Off On 240000h 2304KB Off Off On Off Off On Off 260000h 2432KB Off Off On Off Off On On 280000h 2560KB Off Off On Off On Off Off 2A0000h 2688KB Off Off On Off On Off On 2C0000h 2816KB Off Off On Off On On Off 2E0000h 2944KB Off Off On Off On On On 300000h 3072KB Off Off On On Off Off Off EMS BUS SIZE SELECT Setting SW3/1 8-bit Closed 16-bit Open