EDIMAX COMPUTER COMPANY 1000A V2.4 NIC Type Ethernet Transfer Rate 10Mbps Data Bus 8-bit ISA Topology Star Linear Bus Wiring Type RG-58A/U 50ohm coaxial Unshielded twisted pair AUI transceiver via DB-15 port Boot ROM Available [Image] I/O BASE ADDRESS Address JP1A JP1B JP1C » 300h Closed Closed Closed 320h Closed Closed Open 340h Closed Open Closed 360h Closed Open Open INTERRUPT SETTINGS IRQ JP1D JP1E JP1F JP1G JP1H JP1I 2 Closed Open Open Open Open Open 3 Open Closed Open Open Open Open 4 Open Open Closed Open Open Open 5 Open Open Open Closed Open Open 6 Open Open Open Open Closed Open 7 Open Open Open Open Open Closed DMA CHANNEL Channel JP1J JP1K JP1L JP1M » Disabled Closed Open Closed Open DMA1 Closed Open Closed Open DMA3 Open Closed Open Closed CONNECTORS Setting Location External power LED. JP2 BOOT ROM ADDRESS Address JP3A JP3B JP3C JP3D C0000h Closed Closed Closed Closed C4000h Open Closed Closed Closed » C8000h Closed Open Closed Closed CC000h Open Open Closed Closed D0000h Closed Closed Open Closed D4000h Open Closed Open Closed D8000h Closed Open Open Closed DC000h Open Open Open Closed CABLE TYPE Type JP4 JP10A-JP10F JP11 » RG-58A/U 50ohm Pins 2 & 3 Open Pins 2 & 3 coaxial Closed Closed AUI transceiver via Pins 1 & 2 Open Pins 1 & 2 DB-15 port Closed Closed Unshielded twisted Pins 1 & 2 Closed Pins 2 & 3 pair Closed Closed BOOT ROM Setting JP5 » Disabled Open Enabled Closed AUTOPOLARITY Setting JP6 » Enabled Pins 1 & 2 Closed Disabled Pins 2 & 3 Closed Note: If disabled, and the network wire polarities are reversed, the card will be damaged. LINK INTEGRITY Setting JP7 » Enabled Pins 2 & 3 Closed Disabled Pins 1 & 2 Closed Note: If this option is disabled, SQE is also disabled and Cable Length is set to 185 meters SIGNAL QUALITY ERROR (SQE) TEST Setting JP8 » Enabled Pins 1 & 2 Closed Disabled Pins 2 & 3 Closed Note:Signal Quality Error (SQE) is a test of the collision circuitry and path. Link integrity must be enabled for SQE to be enabled. CABLE LENGTH SELECT Setting JP13 » 185 meters Pins 1 & 2 Closed 305 meters Pins 2 & 3 Closed Note: All cards on the network segment must have this function set the same. Link integrity must be enabled to select long cable length. FACTORY CONFIGURED SETTINGS Jumper Setting JP9 Unused DIAGNOSTIC LED(S) LED Color Status Condition LED1 Yellow Off Normal operation LED1 Yellow On A reversed twisted pair is detected and corrected LED2 Green On Twisted pair network connection is good LED2 Green Off Twisted pair network connection is broken