ADVANCED INTERLINK CORPORATION AICEther-8/10BT (No Boot ROM) NIC Type Ethernet Transfer Rate 10Mbps Data Bus 8-bit ISA Topology Star Wiring Type Unshielded twisted pair Boot ROM Not available [Image] SEGMENT LENGTH Maximum Segment Length JP1 100 meters Closed 300 meters Open Note:Segment length is the distance from the card to the hub. I/O BASE ADDRESS Address JP2D JP2E 200h Closed Closed 210h Closed Open » 300h Open Closed 310h Open Open INTERRUPT REQUEST IRQ JP2F JP2G JP2H 2 Closed Open Open » 3 Open Closed Open 5 Open Open Closed RECEIVE WIRE POLARITY Mode SW1 » Normal On Inverted Off Note:If the diagnostic LEDs indicate that the receive wires' polarities are reversed (LED1 Off, Hub LED On) you can TX/RX CROSSOVER Mode SW2 » Normal On Crossover Off Note:If the diagnostic LEDs indicate that the transmit & receive wires are reversed (LED1 Off, Hub LED Off) you can correct the problem by using the crossover option. FACTORY CONFIGURED SETTINGS Jumper Setting JP2A Unused JP2B Unused JP2C Unused JP4 Unused DIAGNOSTIC LED(S) LED1 Hub LED Condition On On Network connection is good Off Off Transmit/Receive crossover at card On Off Receive polarity reversed at hub Off On Receive polarity reversed at card Note:The Hub LED is located on the hub, not on the card.