ANCO TECHNOLOGY, INC. E5002 NIC Type Ethernet Transfer Rate 10Mbps Data Bus 16-bit ISA Topology Star Wiring Type Unshielded twisted pair AUI transceiver via DB-15 port Boot ROM Available [Image] INTERRUPT REQUEST IRQ JP1A JP1B JP1C JP1D JP1E JP1F JP1G 2/9 Closed Open Open Open Open Open Open » 3 Open Closed Open Open Open Open Open 6 Open Open Closed Open Open Open Open 6 Open Open Open Closed Open Open Open 7 Open Open Open Open Closed Open Open 11 Open Open Open Open Open Closed Open 12 Open Open Open Open Open Open Closed LINK INTEGRITY TEST Setting JP31 » Enabled Pins 1 & 2 Closed Disabled Pins 2 & 3 Closed Note:Link Integrity is only used with 10Base-T wiring. When using an AUI transciever, the test should be disabled. CABLE TYPE Type SW1/2 » Shielded/Unshielded twisted pair On AUI transceiver via DB-15 port Off I/O BASE ADDRESS Address SW1/3 SW1/4 » 300-31Fh On On 320-33Fh Off On 340-35Fh On Off 360-37Fh Off Of BOOT ROM ADDRESS Address SW1/5 SW1/6 SW1/7 SW1/8 Disabled Off Off Off Off C4000h On On On Off C8000h Off On On Off CC000h On Off On Off D0000h Off Off On Off D4000h On On Off Off D8000h Off On Off Off DC000h On Off Off Off DIAGNOSTIC LED(S) LED Link Integrity Status Condition LED1 Enabled On Twisted pair network connection good LED1 Enabled Off Twisted pair network connection broken LED1 Disabled On Data is being received power LED1 Disabled Off Data is not being received power Note:The condition designated by LED1 depends on the setting of the link integrity switch SW1/1.