ZOBEX ZOBEX 4HDC-62W Data Bus 8-bit ISA Card Size Three-quarter length, full-height card Hard Drives supported Four ST-506/412(MFM) drives Floppy drives supported None [Image] CONNECTIONS Function Location Function Location 34-pin control cable J1 20-pin data cable J4 connector connector 20-pin data cable J2 20-pin data cable J5 connector - drive 0 connector 20-pin data cable J3 connector - drive 1 USER CONFIGURABLE SETTINGS Function Label Position » IRQ 5 enable JP4/1 Closed IRQ 5 disable JP4/1 Open » Factory configured - do not P2 Open alter » Write Protect drive 0 P3/pins 1 & 2 Open disabled Write Protect drive 0 P3/pins 1 & 2 Closed enabled » Write Protect drive 1 P3/pins 3 & 4 Open disabled Write Protect drive 1 P3/pins 3 & 4 Closed enabled » Write Protect drive 2 P3/pins 5 & 6 Open disabled Write Protect drive 2 P3/pins 5 & 6 Closed enabled » Write Protect drive 3 P3/pins 7 & 8 Open disabled Write Protect drive 3 P3/pins 7 & 8 Closed enabled » Factory configured - do not SW1/1 Off alter (Ext. Stat. Reg. Bit 4) » Factory configured - do not SW1/2 Off alter (Ext. Stat. Reg. Bit 5) » Factory configured - do not SW1/3 Off alter (Ext. Stat. Reg. Bit 6) » Factory configured - do not SW1/4 Off alter (Ext. Stat. Reg. Bit 7) » Factory configured - do not SW2/7 Unidentified alter » Factory configured - do not SW2/8 Unidentified alter PIN 2 CABLE SELECTION FOR CABLE J1 Setting P1/1 P1/2 P1/3 P1/4 Change Cartridge Open Open Open Closed Signal Head Select Open Open Closed Open » Reduced Write Open Closed Open Open Current Disable pin 2 3 Closed Open Open Open Note: Select the ‘Head Select’ setting if the attached drive is large capacity with more than 8 heads. DMA CHANNEL SELECTION Channel JP4/1 JP4/2 » DMA 3 disabled Open Open DMA 3 enabled Closed Closed BASE ADDRESS SELECTION Setting SW2/1 SW2/2 SW2/3 SW2/4 SW2/5 SW2/6 » 300h On On On Off Off On