SCIENTIFIC MICRO SYSTEMS, INC. OMTI 7100, OMTI 7200, OMTI 7400 Data bus: 50-pin SCSI interface Size: 5.25" FF Hard drive supported: Up to two ST506/412 MFM drives, up to two ESDI drive Floppy drives supported: Two 360KB, 720KB, 1.2MB, 1.44Mb or 8" drives (except 7100) [Image] CONNECTIONS Function Location 50-pin SCSI interface J1 34-pin ESDI or MFM disk control connector J2 20-pin data cable connector J3 20-pin data cable connector J4 34-pin floppy drive connector (not in 7100) J7 50-pin tape drive connector (7400 only) J8 DC power connector J10 USER CONFIGURABLE SETTINGS Function Location Setting » SCSI parity enabled W4 closed » SCSI parity disabled W4 open » Spindle motor starts on power up W5 closed (used with ESDI) » Spindle motor starts on command W5 open only (used with ESDI) » ST506/412 interface for drive W6 open select 1 enabled » ESDI interface for drive select W6 closed 1 enabled » ST506/412 interface for drive W7 open select 2 enabled » ESDI interface for drive select W7 closed 2 enabled » Factory configured - do not W8 N/A alter » Factory configured - do not W9 N/A alter » Factory configured - do not W10 N/A alter » Factory configured - do not W11 N/A alter » Factory configured - do not W12 N/A alter » Factory configured - do not W13 N/A alter » TRMPWR supplied by board W14/pins 1 & 2 closed » TRMPWR supplied by SCSI bus W14/pins 2 & 3 closed » Ready signal from pin 2 to FDC W15 open 765 disabled » Ready signal from pin 2 to FDC W15 closed 765 enabled » Ready signal from pin 34 to FDC W16 open 765 disabled » Ready signal from pin 34 to FDC W16 closed 765 enabled » Factory configured - do not W17 N/A alter » Motor on signal delay enabled W18 open » Motor on signal enabled W18 closed » Factory configured - do not W21 N/A alter » Factory configured - do not W22 N/A alter » QIC-02 (tape drive) parity W25 closed enabled (7400 only) » QIC-02 (tape drive) parity W25 open disabled (7400 only) » Factory configured - do not W29 N/A alter » Disk change detection from FDD W37 closed connector pin 2 enabled » Disk change detection from FDD W37 open connector pin 2 disabled » Disk change detection from FDD W38 closed connector pin 34 enabled » Disk change detection from FDD W38 open connector pin 34 disabled » Clear disk change signal W39 open disabled » Clear disk change signal enabled W39/pins 1 & 2 closed Note: Drive select 1 & 2 refer to the drive select jumper setting on the drive itself and should be set to 1 & 2 respectively. When W39/pins 1 & 2 closed drive select 4 must not be used. Jumpers W15, W16, W17, W18, W37, W38, W39 refer to flexible disk drives and apply only to models 7200 & 7400. SCSI ADDRESS SCSI ID W1 W2 W3 » 0 open open open » 1 closed open open » 2 open closed open » 3 closed closed open » 4 open open closed » 5 closed open closed » 6 open closed close » 7 closed closed closed