Right-click the Hole positioning capture and
select Unset Current form the contextual menu, right-click the
Surface positioning capture and select Set Current
form the contextual menu.
-
Select the datum reference frame in the Semantic
Tolerancing Advisor dialog box.
-
Select the surface as shown on the part.
|
|
|
The Semantic Tolerancing Advisor dialog box is updated.
Note the geometric feature type: One surface. |
-
Click the Profile of a Surface icon:
|
The Geometrical Tolerance dialog box appears. |
-
Set the numerical value to 0.5 mm.
-
Select the Tolerance Zone tab and check the
Shifted Profile Tolerance icon.
-
Click the OK in the dialog box.
|
The geometrical tolerance is created. |
|
The geometrical tolerance is created in the specification tree. |
-
Right-click the Surface positioning capture and
select Unset Current form the contextual menu.
|